CVE-2026-11845
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedThe iVEC-IEI Virtualization Edge Computer developed by IEI Integration Corp has a OS Command Injection vulnerability, allowing privileged remote attackers to inject arbitrary OS commands and execute them on the device.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceThe iVEC-IEI Virtualization Edge Computer by IEI Integration Corp contains an OS Command Injection vulnerability. This allows an attacker with privileged remote access to inject arbitrary operating system commands that are executed with the privileges of the vulnerable application, potentially leading to full device compromise.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- High
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device modelPhysically inspect the device or query the device's system information/network discovery to confirm it is an iVEC-IEI Virtualization Edge Computer by IEI Integration CorpAffected if The device is an iVEC-IEI Virtualization Edge Computer from IEI Integration Corp
-
Locate the firmware versionAccess the device management interface or check system files/boot logs to find the installed firmware versionAffected if The installed firmware version predates any vendor-supplied patches (compare against vendor release notes when available)
-
Check for remote management exposureReview network configuration and firewall rules to determine if the device's management interface (web UI, SSH, Telnet) is accessible from untrusted networksAffected if Management interfaces are exposed to untrusted networks or the internet
-
Verify privileged remote access statusInspect authentication settings to determine if privileged (administrator-level) remote access is enabled and accessibleAffected if Privileged remote access is enabled and reachable from non-trusted networks
-
Review command execution loggingExamine system logs, audit logs, and command history for unexpected or unauthorized command executions, particularly those originating from the web interface or APIAffected if Unknown or suspicious commands appear in logs, especially those executed by the web application
A user is affected if they operate an iVEC-IEI Virtualization Edge Computer with management interfaces exposed to untrusted networks and the installed firmware has not been patched by the vendor.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply vendor-supplied firmware updates when available; until then, restrict network access to the device's management interfaces to trusted sources only and monitor for indicators of compromise.
- Consultation6.0 h
- Implementation8.0 h
- Testing4.0 h
- Review / QA3.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,048.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2026-11845 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2026-11845 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm