InjectionWeakness · CWE-74

CVE-2026-12808

MEDIUM · 6.3 CVSS v3.1 Published 2026-06-21
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
69/100
Remediation priority · Elevated
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability was determined in Edimax BR-6478AC V2 1.23. This impacts the function stainfo of the file /goform/stainfo of the component POST Request Handler. This manipulation of the argument interface causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

The Edimax BR-6478AC V2 router firmware 1.23 contains a command injection vulnerability in the /goform/stainfo POST request handler. The 'interface' parameter is passed unsanitized to a system call, allowing remote attackers to execute arbitrary commands by injecting shell metacharacters.

MitigationSince Edimax did not respond to the disclosure and no firmware patch exists, mitigate by disabling remote web management, placing the device behind a NAT/firewall, or replacing the end-of-life device with a supported model.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
Low
Availability
Low

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify device model
    Access the router admin interface and check the device model information, typically found on the status page or in the system settings. Look for 'BR-6478AC V2' model designation.
    Affected if The device is not an Edimax BR-6478AC V2 router - different models are not affected by this specific CVE.
  2. Check firmware version
    In the router admin panel, navigate to the firmware/version information section, typically under System > Firmware Upgrade or Status > Device Information. Verify the firmware version is exactly 1.23.
    Affected if The installed firmware version is 1.23 - only this specific version is confirmed vulnerable.
  3. Confirm web management interface exposure
    Check the router's remote management settings under Advanced > Remote Management or Access Control. Verify whether 'Enable Remote Management' or similar option is turned ON, allowing access to the web interface from outside the local network.
    Affected if Remote web management is enabled - the vulnerability is exploitable remotely, so external access to the admin interface is required for exploitation.
  4. Verify stainfo form handler presence
    Send a POST request to http://[router-ip]/goform/stainfo with any payload to confirm the endpoint exists and responds. A vulnerable device will accept the request; a patched or unaffected device may return an error or different response.
    Affected if The /goform/stainfo endpoint responds to POST requests - this confirms the vulnerable handler is present and accessible.

You are affected if you have an Edimax BR-6478AC V2 router running firmware version 1.23 with remote web management enabled and the stainfo form endpoint is accessible.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Since Edimax did not respond to the disclosure and no firmware patch exists, mitigate by disabling remote web management, placing the device behind a NAT/firewall, or replacing the end-of-life device with a supported model.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation6.0 h
  • Testing4.0 h
  • Review / QA2.0 h
16.0 hours of engineering $2,840
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,544.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-12808 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-12808 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data