CVE-2026-20738
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedUntrusted pointer dereference for some Intel(R) QuickAssist Adapter 8960 software before version 1.13 within Ring 3: User Applications may allow an escalation of privilege. Unprivileged software adversary with an authenticated user combined with a low complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are not present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceUntrusted pointer dereference vulnerability in Intel QuickAssist Adapter 8960 software (Ring 3/User Applications) before version 1.13 allows an authenticated local user to escalate privileges to potentially gain high confidentiality, integrity, and availability impacts. The attack is low complexity, requires local access, and no user interaction.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- Low
- Authentication
- X
- User interaction
- None
- Scope
- X
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Check if Intel QuickAssist Adapter 8960 software is installedQuery the Windows registry for the presence of Intel QuickAssist software. Look in HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall for entries containing 'QuickAssist' or '8960', or check for the QATools service using 'sc query' command.Affected if No Intel QuickAssist Adapter 8960 software entry is found in the registry or the QATools service does not exist, then the system is not affected.
-
Identify the installed version of Intel QuickAssist Adapter 8960 softwareRetrieve the version number from the registry key found in step 1 (look for the 'DisplayVersion' value) or use 'wmic product get name,version' to list installed Intel software and note the version number.Affected if The software is installed but the version cannot be determined or is lower than 1.13, treat it as potentially affected.
-
Compare the installed version against the fixed version 1.13Compare the version number obtained in step 2 to 1.13 using standard version comparison (for example, 1.12.x, 1.10, 1.0 are all below 1.13).Affected if The installed version is any version before 1.13 (for example, 1.12, 1.11, 1.10, 1.0.x), the system is vulnerable.
-
Verify if the QuickAssist user-mode component is runningCheck for the QATools or QuickAssist user-mode process using Task Manager or 'tasklist /FI "IMAGENAME eq *.exe"' command, or check for the presence of QATools service using 'sc query QATools'.Affected if The software version is below 1.13 AND the QuickAssist user-mode component is currently running or configured to run, the vulnerability is present and exploitable.
The system is affected if Intel QuickAssist Adapter 8960 software is installed with any version earlier than 1.13 and the user-mode component is present on the system.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedUpdate Intel QuickAssist Adapter 8960 software to version 1.13 or later to remediate the untrusted pointer dereference vulnerability.
Intel QuickAssist Adapter 8960 software version 1.13 or later
- 1. Identify the current version of Intel(R) QuickAssist Adapter 8960 software installed on the system
- 2. Navigate to Intel's official support website or contact Intel to obtain version 1.13 or later of the QuickAssist Adapter 8960 software
- 3. Download the updated software package from a verified Intel source
- 4. Follow Intel's documented upgrade procedure for the QuickAssist Adapter software
- 5. Apply the update ensuring proper system backup beforehand if required
- 6. Restart the system or affected services as instructed by the update documentation
- 7. Verify the installed version is 1.13 or later using system inventory or Intel management tools
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation6.0 h
- Testing8.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,080.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2026-20738 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2026-20738 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data