CVE-2026-22910
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedThe device is deployed with weak and publicly known default passwords for certain hidden user levels, increasing the risk of unauthorized access. This represents a high risk to the integrity of the system.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceThe vulnerability involves network devices shipped with weak, publicly known default passwords for hidden administrative user accounts. Attackers with knowledge of these default credentials can gain unauthorized privileged access to the device, compromising system integrity and potentially enabling further network penetration.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE dataall versionsCVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- None
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm device model and firmwareIdentify if the target device is a Sick Tdc X401gl by checking the device label, web interface, or system information page. Note that all firmware versions are affected.Affected if The device is a Sick Tdc X401gl
-
Enumerate user accounts on the deviceAccess the device administrative interface and navigate to user management or account settings. Look for any hidden, undocumented, or non-standard administrative accounts beyond the expected named users.Affected if Hidden or undocumented administrative user accounts exist on the device
-
Check for default or weak passwords in useReview the authentication configuration or attempt to verify whether any hidden accounts are using default, factory-set, or easily guessable passwords. Compare against publicly known default credentials for this device model.Affected if Hidden accounts are using default, publicly known, or weak passwords
-
Review authentication logs for compromiseExamine device logs, system logs, or authentication audit trails for successful or failed login attempts using default credentials or unusual privileged account activity.Affected if Logs show successful logins using default credentials or unauthorized privileged access
If the device is a Sick Tdc X401gl with hidden administrative accounts using default or publicly known passwords, the environment is affected by this vulnerability.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataImmediately change all default passwords for hidden accounts, disable unused hidden accounts, and implement a firmware update that enforces unique strong passwords on first login and removes or文档ates hidden backdoor accounts.
- Consultation6.0 h
- Implementation12.0 h
- Testing6.0 h
- Review / QA3.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,680.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2026-22910 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2026-22910 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm