Missing AuthenticationWeakness · CWE-306

CVE-2026-25137

CRITICAL · 9.1 CVSS v3.1 Published 2026-02-02
Patch available
A vendor patch is available. No clean upgrade release — apply the published patch.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click Patch available

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
The NixOs Odoo package is an open source ERP and CRM system. From 21.11 to before 25.11 and 26.05, every NixOS based Odoo setup publicly exposes the database manager without any authentication. This allows unauthorized actors to delete and download the entire database, including Odoos file store. Unauthorized access is evident from http requests. If kept, searching access logs and/or Odoos log for requests to /web/database can give indicators, if this has been actively exploited. The database manager is a featured intended for development and not meant to be publicly reachable. On other setups, a master password acts as 2nd line of defence. However, due to the nature of NixOS, Odoo is not able to modify its own configuration file and thus unable to persist the auto-generated password. This also applies when manually setting a master password in the web-UI. This means, the password is lost when restarting Odoo. When no password is set, the user is prompted to set one directly via the database manager. This requires no authentication or action by any authorized user or the system administrator. Thus, the database is effectively world readable by anyone able to reach Odoo. This vulnerability is fixed in 25.11 and 26.05.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis
How this class of weakness works · CWE-306

A sensitive function is reachable with no authentication at all, so anyone who finds the endpoint can use it. These are routinely discovered by automated scanning. The fix is to require and enforce authentication on every privileged path, with no exceptions left open.

General guidance for the missing authentication class — the official description and references above are authoritative for this specific CVE. Want a bespoke review and a reviewed fix? Ask our team →

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Patch available Apply the vendor patch
Vendor patch github.com →
Recommended fix High confidence

NixOS 25.11 or NixOS 26.05

  1. Update your NixOS channel to receive the fixed package: `sudo nix-channel --update`
  2. Upgrade to NixOS 25.11 or newer by updating your configuration.nix with `system.stateVersion = "25.11";` or equivalent
  3. Rebuild your NixOS system: `sudo nixos-rebuild switch`
  4. After upgrade, verify the Odoo service is running correctly: `systemctl status odoo`
  5. Check that the database manager is no longer accessible without authentication by attempting to access /web/database (should require auth)
  6. If you need a specific version, ensure your Nixpkgs pin includes a commit after the fix (PR #485310)
Caveat Minor: Review Odoo configuration after upgrade as default settings may differ; ensure any custom modules are compatible with the new Odoo version

Generated from the published advisory — verify against the referenced sources before acting.

We can apply and verify the patch for your build — typical engagement from $2,300. Get the patch applied

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-25137 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-25137 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data