CVE-2026-25787
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedAffected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a benign user with appropriate rights accesses the "Motion Control Diagnostics" parameters page, the malicious code would be executed in the scope of their web session.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThis is a stored Cross-Site Scripting (XSS) vulnerability in the web interface of affected industrial devices. An authenticated attacker with TIA project download privileges can inject malicious JavaScript into the Technology Object (TO) name field. When other authorized users access the 'Motion Control Diagnostics' page, the unsanitized TO name is rendered in HTML, causing the attacker's script to execute in the victim's browser session.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- High
- User interaction
- None
- Scope
- Changed
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify TIA Portal installation and versionCheck the installed Siemens TIA Portal version by viewing the program in Add/Remove Programs (Windows) or checking the installation directory for version information. Compare your version against the affected range.Affected if The installed TIA Portal version is within the affected range and the web interface is enabled.
-
Verify Motion Control Diagnostics web interface is enabledCheck if the web-based Motion Control Diagnostics feature is enabled in the TIA Portal project settings or runtime configuration. This is typically accessible through the TIA Portal's web server configuration.Affected if The Motion Control Diagnostics web interface is enabled and accessible over the network.
-
Confirm user accounts with TIA project download privileges existReview the user management or project protection settings in TIA Portal to identify accounts that have permission to modify Technology Objects and download projects. Check the user roles and privileges configuration.Affected if There are authenticated users with TIA project download privileges who can access the web interface.
-
Inspect Technology Object names for unsanitized contentAccess the Motion Control Diagnostics page via the web interface and examine how Technology Object names are displayed. Use browser developer tools or HTTP response inspection to observe if the TO name field reflects raw input without proper HTML encoding.Affected if The Technology Object names are displayed without proper output encoding, allowing script execution.
-
Verify stored XSS payload executionIf you have a TO with a test payload containing script tags in its name, access the Motion Control Diagnostics page and check if the JavaScript executes in your browser context.Affected if Malicious JavaScript embedded in the TO name field executes when other users view the Motion Control Diagnostics page.
A user is affected if they run a vulnerable TIA Portal version with the Motion Control Diagnostics web interface enabled and have users with TIA project download privileges accessing the exposed interface.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataImplement strict input validation for Technology Object names during project import/download and apply proper output encoding/sanitization before rendering any TO names on the Motion Control Diagnostics page.
- Consultation4.0 h
- Implementation8.0 h
- Testing4.0 h
- Review / QA3.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,408.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2026-25787 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2026-25787 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm