CWE-114Weakness · CWE-114

CVE-2026-26945

MEDIUM · 5.3 CVSS v3.1 Published 2026-03-18
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
55/100
Remediation priority · Elevated
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Dell Integrated Dell Remote Access Controller 9, 14G versions prior to 7.00.00.181, 15G and 16G versions prior to 7.20.10.50 and Dell Integrated Dell Remote Access Controller 10, 17G versions prior to 1.20.25.00, contain a Process Control vulnerability. A high privileged attacker with adjacent network access could potentially exploit this vulnerability, leading to code execution.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Dell iDRAC firmware contains a Process Control vulnerability allowing a high-privileged attacker with adjacent network access to potentially achieve code execution. Affected versions span multiple iDRAC generations (9/10, 14G/15G/16G/17G) with specific patch thresholds for each platform.

MitigationUpdate iDRAC firmware to version 7.00.00.181 or later (9/14G), 7.20.10.50 or later (15G/16G), or 1.20.25.00 or later (10/17G). Limit adjacent network access and follow least-privilege principles for iDRAC user accounts.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Adjacent
Complexity
High
Privileges
High
User interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
High
Availability
Low

CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:H/A:L

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Determine iDRAC firmware version
    Access the iDRAC web interface and navigate to 'iDRAC Settings' > 'Overview' > 'Server' > 'Properties' > 'Summary' to view the firmware version. Alternatively, use the RACADM command: racadm get iDRAC.WebServer.Embedded or run 'racadm getversion' via SSH or local RACADM.
    Affected if The installed version falls within the affected ranges: versions before 7.00.00.181 for iDRAC 9/14G, before 7.20.10.50 for iDRAC 15G/16G, or before 1.20.25.00 for iDRAC 10/17G.
  2. Identify iDRAC generation
    Check the hardware model via iDRAC web interface at 'Server' > 'Hardware' > 'System' or use RACADM command: racadm get System.PowerSupply. Verify whether the server is a 14G, 15G, 16G, or 17G generation model, or iDRAC version 9 or 10.
    Affected if The server belongs to an affected iDRAC generation (9, 10, 14G, 15G, 16G, or 17G) and the firmware version is below the patched thresholds.
  3. Assess network exposure
    Review iDRAC network configuration in the web UI under 'iDRAC Settings' > 'Network' > 'IPMI Settings' or use RACADM: racadm get iDRAC.NIC. Check if iDRAC is accessible on the corporate network, VLAN, or any network segment accessible to adjacent attackers.
    Affected if iDRAC is reachable from network segments accessible to untrusted adjacent attackers, enabling the adjacent network attack vector described in the CVE.
  4. Review iDRAC user privileges
    List iDRAC user accounts via web UI at 'iDRAC Settings' > 'Users' > 'Local Users' or run RACADM command: racadm get iDRAC.Users. Identify accounts with 'Administrator' or high-privilege roles.
    Affected if High-privilege iDRAC user accounts exist and could be compromised, as the CVE requires a high-privileged attacker to exploit this vulnerability.

You are affected if your Dell server runs iDRAC firmware version below 7.00.00.181 (9/14G), below 7.20.10.50 (15G/16G), or below 1.20.25.00 (10/17G) and the iDRAC is accessible from network segments accessible to adjacent attackers.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Update iDRAC firmware to version 7.00.00.181 or later (9/14G), 7.20.10.50 or later (15G/16G), or 1.20.25.00 or later (10/17G). Limit adjacent network access and follow least-privilege principles for iDRAC user accounts.

Recommended fix High confidence

iDRAC 9/14G: 7.00.00.181 or later; iDRAC 15G/16G: 7.20.10.50 or later; iDRAC 10/17G: 1.20.25.00 or later

  1. Identify the current iDRAC version by logging into the iDRAC web interface or using racadm command: racadm get iDRAC.Info
  2. Determine the iDRAC generation (9, 14G, 15G, 16G, 10, or 17G) from the hardware platform
  3. Download the appropriate iDRAC firmware update from Dell Support at www.dell.com - select your specific server model and iDRAC version
  4. Upload the firmware update via iDRAC web interface under 'iDRAC Settings > Firmware Update' or using racadm: racadm update -f firmware_file.exe
  5. Apply the update and allow the iDRAC to reboot - this may take several minutes
  6. Verify the new firmware version is installed: racadm get iDRAC.Info
Caveat Firmware updates to iDRAC may briefly interrupt remote management capabilities; plan during maintenance window

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA4.0 h
22.0 hours of engineering $3,860
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-26945 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-26945 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data