Fd8136 FirmwareOperating system · Vivotek

CVE-2026-30652

HIGH · 8.8 CVSS v3.1 Published 2026-06-02
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
94/100
Remediation priority · Urgent
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A remote buffer overflow vulnerability exists in the /cgi-bin/dido/setdo.cgi endpoint of the admin interface of Vivotek FD8136 cameras running firmware version FD8136-VVTK-0300a. This flaw allows an authenticated attacker to execute arbitrary code as root on the device.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A buffer overflow vulnerability exists in the /cgi-bin/dido/setdo.cgi endpoint of Vivotek FD8136 IP cameras (firmware FD8136-VVTK-0300a). An authenticated attacker can overflow a buffer to achieve arbitrary code execution with root privileges on the device.

MitigationUpdate to patched firmware when available from Vivotek; until then, restrict network access to the admin interface and disable remote management if possible.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Fd8136 FirmwareOperating system
Affected:= 0300a

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the device model
    Access the camera's web interface or check the device's network response headers to confirm it is a Vivotek FD8136 camera
    Affected if The device is NOT a Vivotek FD8136 model, then it is not affected by this CVE
  2. Check the firmware version
    Navigate to the camera's admin page, typically under System > Information, or query the device's /cgi-bin/sysinfo.cgi endpoint to retrieve the firmware version
    Affected if The firmware version is exactly 0300a (FD8136-VVTK-0300a), then the device is vulnerable
  3. Verify the vulnerable CGI endpoint exists
    Attempt to access the URL path /cgi-bin/dido/setdo.cgi on the camera (note: this requires authentication to exploit but the endpoint may respond to probe requests)
    Affected if The endpoint responds, indicating the dido module is present and the attack surface exists

The device is affected only if it is a Vivotek FD8136 camera running firmware version exactly 0300a and the /cgi-bin/dido/setdo.cgi endpoint is accessible.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Update to patched firmware when available from Vivotek; until then, restrict network access to the admin interface and disable remote management if possible.

Fix this in Fd8136 Firmware Scoped from the published advisory
  • Consultation2.0 h
  • Implementation4.0 h
  • Testing3.0 h
  • Review / QA2.0 h
11.0 hours of engineering $1,930
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,088.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-30652 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-30652 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data