CVE-2026-33774
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedAn Improper Check for Unusual or Exceptional Conditions vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on MX Series allows an unauthenticated, network-based attacker to bypass the configured firewall filter and access the control-plane of the device. On MX platforms with MPC10, MPC11, LC4800 or LC9600 line cards, and MX304, firewall filters applied on a loopback interface lo0.n (where n is a non-0 number) don't get executed when lo0.n is in the global VRF / default routing-instance. An affected configuration would be: user@host# show configuration interfaces lo0 | display set set interfaces lo0 unit 1 family inet filter input <filter-name> where a firewall filter is applied to a non-0 loopback interface, but that loopback interface is not referred to in any routing-instance (RI) configuration, which implies that it's used in the default RI. The issue can be observed with the CLI command: user@device> show firewall counter filter <filter_name> not showing any matches. This issue affects Junos OS on MX Series: * all versions before 23.2R2-S6, * 23.4 versions before 23.4R2-S7, * 24.2 versions before 24.2R2, * 24.4 versions before 24.4R2.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceImproper check in the packet forwarding engine (PFE) causes firewall filters on non-zero loopback interfaces (lo0.n) to not execute when those interfaces are in the global VRF/default routing-instance, allowing unauthenticated attackers to bypass control-plane filtering on affected MX Series devices with MPC10, MPC11, LC4800, LC9600 line cards or MX304.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 23.2= 23.2= 23.4= 24.2= 24.4CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- Low
- Integrity
- None
- Availability
- None
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm device is MX SeriesRun 'show chassis hardware' or 'show system information' to verify the device is an MX Series routerAffected if Device is not an MX Series model
-
Verify line card typeRun 'show chassis hardware' and identify if the device has MPC10, MPC11, LC4800, LC9600 line cards or is an MX304Affected if Device does not have any of the listed line cards (MPC10, MPC11, LC4800, LC9600) and is not an MX304
-
Check installed Junos versionRun 'show version' to identify the exact Junos OS version installedAffected if Version is not in the affected range: < 23.2, 23.2, 23.4, 24.2, or 24.4
-
Identify non-zero loopback interfaces in global VRFRun 'show configuration interfaces lo0' and 'show configuration routing-instances' to find lo0.n interfaces configured in the default/global routing instanceAffected if No lo0.n (lo0.1, lo0.2, etc.) interfaces exist in the global VRF/default routing-instance
-
Check for firewall filters on loopback interfacesRun 'show configuration interfaces lo0.n | find filter' for each lo0.n interface to see if input or output firewall filters are appliedAffected if No firewall filters are applied to non-zero loopback interfaces in the global VRF
Device is affected if it is an MX Series with MPC10/MPC11/LC4800/LC9600 line cards or MX304, running a vulnerable Junos version, with lo0.n interfaces in the global VRF that have firewall filters applied but those filters are not executing (counter shows no hits).
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped23.2
Apply the appropriate Junos OS patch (23.2R2-S6 or later, 23.4R2-S7 or later, 24.2R2 or later, or 24.4R2 or later) to affected MX Series devices with the specified line cards. Verify firewall filter counters are incrementing after the upgrade.
23.4R2-S7, 24.2R2, or 24.4R2 (any fixed release appropriate for deployment timeline)
- 1. Identify the current Junos OS version on the MX Series device using 'show version'
- 2. Confirm the device has an affected line card (MPC10, MPC11, LC4800, LC9600) or is an MX304 using 'show chassis hardware'
- 3. Verify the affected configuration: check if firewall filters are applied to non-0 loopback units (lo0.n where n>0) that are not bound to any routing-instance using 'show configuration interfaces lo0'
- 4. Download the appropriate fixed Junos OS release: 23.2R2-S6 or later, 23.4R2-S7 or later, 24.2R2 or later, or 24.4R2 or later
- 5. Upload the Junos OS upgrade package to the device using 'file copy' or FTP/SCP
- 6. Install the upgrade using 'request system software add <package_name>' with appropriate reboot
- 7. After reboot, verify the fix by applying a test firewall filter to lo0.n and confirming counters increment using 'show firewall counter filter <filter_name>'
- 8. Alternatively, migrate affected loopback interfaces into explicit routing-instance configurations as a configuration-based workaround
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation8.0 h
- Testing12.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,616.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2026-33774 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2026-33774 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data