CVE-2026-36176
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedGNCC GP5 v7.1.76 was discovered to store pre-signed Backblaze B2 upload URLs (PUT requests) in plaintext to the serial console. This allows physically-proximate attackers to extract these active tokens to perform unauthorized operations via monitoring the serial UART interface.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceGNCC GP5 firmware v7.1.76 writes pre-signed Backblaze B2 upload URLs containing active authentication tokens in plaintext to the serial UART console. An attacker with physical proximity can monitor the serial interface and extract these tokens to perform unauthorized B2 storage operations.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Physical
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Changed
- Confidentiality
- High
- Integrity
- High
- Availability
- None
CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device modelCheck the device label, boot output, or PCB marking for 'GNCC GP5' model identificationAffected if Device is not a GNCC GP5 unit - not affected
-
Check firmware versionAccess the device's web interface, administrative console, or check the firmware file; look for version string '7.1.76' or compare against the affected versionAffected if Firmware version is not 7.1.76 - likely not affected (though older versions may also have this issue)
-
Verify B2 cloud storage is configuredCheck device settings or configuration files for Backblaze B2 storage account integration; look for B2 key ID, bucket name, or endpoint configurationAffected if B2 storage is not configured/enabled - the specific token leakage vector is not active
-
Confirm serial UART console is accessibleLocate the UART pins on the device PCB; connect a serial adapter at standard baud rates and verify console output is readableAffected if Serial UART console is not accessible or disabled - limited exposure to physical attackers
-
Inspect serial output for plaintext URLsCapture serial console output during normal device operation, specifically during upload events; search for strings containing 'backblaze.com' or 'b2cloud.io' with 'Authorization' or token-like parameters in plaintextAffected if Serial output contains pre-signed B2 URLs with active tokens in plaintext - CONFIRMED AFFECTED
Device is affected if it is a GNCC GP5 running firmware 7.1.76 with B2 storage configured and the serial UART console is accessible, revealing plaintext pre-signed upload URLs with active authentication tokens.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataModify firmware to prevent logging or displaying pre-signed URLs and sensitive tokens to the serial console; implement secure logging that redacts or omits authentication credentials from all console output.
- Consultation4.0 h
- Implementation8.0 h
- Testing6.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2026-36176 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2026-36176 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data