Classic Buffer OverflowWeakness · CWE-120

CVE-2026-36810

HIGH · 7.5 CVSS v3.1 Published 2026-06-09
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
84/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Shenzhen Tenda Technology Co., Ltd Tenda W15E v15.11.0.10 was discovered to contain a buffer overflow in the gotoUrl parameter of the formPortalAuth function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted HTTP request.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Buffer overflow vulnerability in Tenda W15E v15.11.0.10 router firmware allows attackers to cause Denial of Service via a crafted HTTP request containing an overly long gotoUrl parameter to the formPortalAuth function.

MitigationApply vendor firmware patch when available; until then, restrict administrative interface access to trusted networks or disable portal auth features if not required.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm device model is Tenda W15E
    Access the router web interface or check the device label/marketing to verify the model number is W15E
    Affected if Device is not a Tenda W15E router
  2. Identify the installed firmware version
    Log into the router admin panel and navigate to System Status or Firmware Upgrade page to view the current firmware version. Alternatively, check via CLI if telnet/ssh is enabled.
    Affected if Firmware version is NOT v15.11.0.10
  3. Verify the web management interface is active
    Attempt to access the router login page over HTTP (port 80) or HTTPS (port 443) from the network. The formPortalAuth function is part of the portal authentication module.
    Affected if Web interface is not accessible or the router has no HTTP service running
  4. Determine if remote management is exposed
    Check the router security settings to see if the web interface is bound to WAN (remote) interfaces or only to LAN. Look for 'Remote Management' or 'Web Management' access restrictions.
    Affected if Web interface is strictly limited to LAN-side access only and not exposed to WAN

You are affected if you have a Tenda W15E router running firmware v15.11.0.10 with the web management interface (portal authentication) accessible either locally or remotely.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply vendor firmware patch when available; until then, restrict administrative interface access to trusted networks or disable portal auth features if not required.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation6.0 h
  • Testing4.0 h
  • Review / QA2.0 h
16.0 hours of engineering $2,840
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,544.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-36810 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-36810 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data