CWE-538Weakness · CWE-538

CVE-2026-5434

MEDIUM · 5.9 CVSS v3.1 Published 2026-05-21
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
68/100
Remediation priority · Elevated
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Honeywell Control Network Module (CNM) contains insertion of sensitive information into an unintended directory. An attacker could exploit this vulnerability through probing system files, potentially resulting in unintended access to protected data. Honeywell recommends updating to the most recent version of this product, service or offering [200.1]. The CNM versions affected are from [100.1, 101.1, 110.1, and 110.2].

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

The Honeywell Control Network Module (CNM) contains a vulnerability where sensitive information is being written to unintended directories. An attacker with the ability to probe system files could exploit this to gain unauthorized access to protected data. This appears to be an information disclosure vulnerability where proper file system segregation or access controls are not being enforced.

MitigationHoneywell recommends updating CNM to version 200.1 to remediate this vulnerability. Organizations should also review file system permissions and audit log configurations to detect any unauthorized access attempts.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
High
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the CNM device on the network
    Locate Honeywell Control Network Module devices in your asset inventory or discover them via network scanning. Note the model number and network location.
    Affected if The device is a Honeywell CNM model
  2. Access CNM firmware version
    Log into the CNM web-based or CLI administration interface and locate the firmware version information, typically found in System Info, About, or Diagnostics sections.
    Affected if The displayed version matches 100.1, 101.1, 110.1, or 110.2
  3. Compare version against affected ranges
    Document the installed firmware version and compare it to the affected versions (100.1, 101.1, 110.1, 110.2) and the fixed version (200.1).
    Affected if Installed version is 100.1, 101.1, 110.1, or 110.2
  4. Inspect file storage locations
    Access the CNM file system through the administrative interface or supported export function. Look for sensitive configuration files, credentials, or data files stored in non-standard directories.
    Affected if Sensitive files are found in directories other than the intended secure storage location
  5. Review authentication configuration
    Check the CNM authentication settings and access control lists to determine if unauthenticated or low-privilege access could reach file system areas.
    Affected if Authentication is configured and the device is accessible on the network

The environment is affected if a Honeywell CNM device is running firmware version 100.1, 101.1, 110.1, or 110.2 and sensitive data may be accessible in unintended directory locations.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Honeywell recommends updating CNM to version 200.1 to remediate this vulnerability. Organizations should also review file system permissions and audit log configurations to detect any unauthorized access attempts.

Recommended fix Moderate confidence

200.1

  1. Contact Honeywell technical support or consult official documentation to obtain the version 200.1 update for the Control Network Module (CNM)
  2. Follow Honeywell's standard firmware/software update procedure for CNM devices
  3. Verify the upgrade was successful by confirming the running version is 200.1
  4. After upgrade, review system logs and access controls to confirm the vulnerability is remediated
Caveat Major version jump from 100.x/110.x to 200.x may introduce functional changes; review release notes for compatibility with existing systems

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation8.0 h
  • Implementation6.0 h
  • Testing12.0 h
  • Review / QA6.0 h
32.0 hours of engineering $5,560
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $8,896.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-5434 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-5434 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data