Unifi ProtectApplication · Ui

CVE-2026-56841

HIGH · 8.8 CVSS v3.1 Published 2026-07-02
Fix available
A fix is available. Upgrade to 7.1.83 or later.
See remediation →
94/100
Remediation priority · Urgent
Remotely reachable Zero-click 8 weeks old

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A malicious actor with access to the network and low privileges could exploit an authenticated SQL Injection vulnerability found in UniFi Protect Application to escalate privileges on the host device.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

An authenticated SQL injection vulnerability exists in UniFi Protect Application that allows a low-privileged attacker with network access to escalate privileges on the host device. The vulnerability stems from improper input sanitization in database queries, enabling malicious SQL commands to be executed through authenticated user inputs.

MitigationUpgrade UniFi Protect Application to the vendor-provided patched version. If no patch is available, implement input validation and parameterized queries for all database interactions, and restrict network access to trusted users.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Unifi ProtectApplication
Affected:< 7.1.83

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify UniFi Protect installation
    Locate the UniFi Protect Application installation and determine its version using the vendor's standard method for checking software version (typically via the controller UI, command line, or system information)
    Affected if UniFi Protect Application is installed and the version is below 7.1.83
  2. Verify installed version number
    Compare your installed UniFi Protect Application version against the affected range: any version less than 7.1.83 is vulnerable
    Affected if The installed version is less than 7.1.83
  3. Assess network exposure
    Determine if the UniFi Protect management interface is accessible from untrusted network segments, as the vulnerability requires network access for an authenticated attacker
    Affected if The UniFi Protect interface is exposed to untrusted or public networks without proper access controls
  4. Review user account configuration
    Check for the presence of low-privileged user accounts within UniFi Protect, as the vulnerability can be exploited by a low-privileged authenticated user
    Affected if Low-privileged accounts exist and can access the UniFi Protect interface from an exposed network

Your environment is affected if UniFi Protect Application is running a version below 7.1.83 and is accessible to authenticated users on untrusted networks.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 7.1.83 or later
Fixed in 7.1.83
Interim mitigation

Upgrade UniFi Protect Application to the vendor-provided patched version. If no patch is available, implement input validation and parameterized queries for all database interactions, and restrict network access to trusted users.

Recommended fix High confidence

UniFi Protect version 7.1.83 or later (recommended: latest stable release)

  1. 1. Log in to the UniFi OS Console hosting the UniFi Protect application
  2. 2. Navigate to the UniFi Protect settings or system management section
  3. 3. Check the current UniFi Protect version to confirm it is below 7.1.83
  4. 4. Initiate the update through the UniFi OS interface - look for an 'Update' or 'Upgrade' option for UniFi Protect
  5. 5. Wait for the update to download and install completely
  6. 6. Verify the installation was successful by checking the new version number is 7.1.83 or higher
  7. 7. Confirm the application is functioning normally after the upgrade

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Unifi Protect Scoped from the published advisory
  • Consultation4.0 h
  • Implementation12.0 h
  • Testing8.0 h
  • Review / QA4.0 h
28.0 hours of engineering $4,880
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,808.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-56841 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-56841 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data