UltravncApplication · Uvnc

CVE-2026-7830

HIGH · 7.4 CVSS v3.1 Published 2026-07-01
Fix available
A fix is available. Upgrade to after 1.8.2.2 or later.
See remediation →
83/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
UltraVNC through 1.8.2.2 uses inadequate cryptography in the MS-Logon II authentication scheme (rfbUltraVNC_MsLogonIIAuth). In rfb/dh.cpp the Diffie-Hellman key exchange is performed with parameters that fit in an unsigned 64-bit integer (DH_MAX_BITS controls the prime size). A 64-bit DH key can be broken by Pollard's rho algorithm in under one second on current hardware. Additionally, the private exponent is generated by the rng() function, which multiplies three libc rand() values seeded from time(NULL). With approximately 31 bits of internal state and a time-based seed, the private exponent is recoverable in under a minute by a passive observer. A network attacker who can observe the MS-Logon II handshake (via sniffing, recording, or man-in-the-middle) can derive the shared DH key and decrypt the encapsulated username and password, resulting in full credential disclosure. This affects legacy MS-Logon II connections; MS-Logon III (X25519 + AES-256-GCM) is unaffected.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

UltraVNC through 1.8.2.2 uses a 64-bit Diffie-Hellman key exchange in MS-Logon II authentication, which is cryptographically broken (Pollard's rho breaks 64-bit DH in under one second). Additionally, the private exponent uses only ~31 bits of entropy from a time-seeded libc rand(), making it recoverable in under a minute. A network attacker observing the handshake can derive the shared key and decrypt credentials.

MitigationDisable MS-Logon II on UltraVNC servers and migrate to MS-Logon III (X25519 + AES-256-GCM), or upgrade UltraVNC if a patched version is available.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
UltravncApplication
Affected:<= 1.8.2.2

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
High
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
None

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm UltraVNC installation
    Check for UltraVNC in installed programs or look for uvnc_service.exe or winvnc.exe processes running on the system
    Affected if UltraVNC version 1.8.2.2 or earlier is installed
  2. Identify UltraVNC version
    Right-click winvnc.exe or uvnc_service.exe, select Properties, and check the File Version field; alternatively, check the version in Windows Programs and Features
    Affected if Version is 1.8.2.2 or any earlier version (versions prior to patch release)
  3. Locate UltraVNC configuration settings
    Check the UltraVNC configuration file (commonly ultravnc.ini in the program directory) or Windows Registry under HKLM\SOFTWARE\UltraVNC for MS-Logon settings
    Affected if A configuration file or registry key for UltraVNC exists with MS-Logon settings
  4. Verify MS-Logon II is enabled
    Look for 'MSLogon' or 'MS-Logon' setting in the UltraVNC configuration file or registry; check value - typically a value of 1 or '1' indicates MS-Logon is enabled
    Affected if MS-Logon is enabled and set to MS-Logon II (the legacy 64-bit DH implementation)
  5. Confirm handshake vulnerability exposure
    If MS-Logon II is enabled, network traffic during authentication uses the weak 64-bit Diffie-Hellman exchange; capture and inspect network handshake packets for DH parameters
    Affected if Network attacker can observe the VNC authentication handshake and MS-Logon II is in use

A user is affected if UltraVNC version 1.8.2.2 or earlier is installed AND MS-Logon II authentication is enabled, allowing a network attacker to intercept and break the weak Diffie-Hellman key exchange.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 1.8.2.2
Interim mitigation

Disable MS-Logon II on UltraVNC servers and migrate to MS-Logon III (X25519 + AES-256-GCM), or upgrade UltraVNC if a patched version is available.

Fix this in Ultravnc Scoped from the published advisory
  • Consultation3.0 h
  • Implementation6.0 h
  • Testing4.0 h
  • Review / QA2.0 h
15.0 hours of engineering $2,640
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,224.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-7830 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-7830 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data