UltravncApplication · Uvnc

CVE-2026-7839

CRITICAL · 9.1 CVSS v3.1 Published 2026-07-01
Fix available
A fix is available. Upgrade to after 1.8.2.2 or later.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click 8 weeks old

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
UltraVNC repeater through 1.8.2.2 initializes the HTTP administration server with a hardcoded default password. In repeater/webgui/settings.c:197, when settings2.txt is absent on first run the repeater writes the literal string "adminadmi2" as the admin password via strcpy_s(saved_password, 64, "adminadmi2"). The HTTP Basic-auth handler wi_decode_auth() checks this password without rate-limiting or lockout. Any remote attacker who can reach the repeater HTTP port (default TCP 80) can authenticate as administrator using the well-known default credential on a fresh or unmodified installation, gaining full control of the repeater configuration including allow/deny rules and session visibility.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

UltraVNC Repeater through 1.8.2.2 initializes its HTTP administration server with a hardcoded default password 'adminadmi2' when settings2.txt is absent on first run. The wi_decode_auth() function in the Basic-auth handler accepts this credential without any rate-limiting or account lockout protection, allowing any remote attacker with network access to TCP port 80 to authenticate as administrator and modify repeater configuration including allow/deny rules and session visibility.

MitigationImmediately change the default admin password from 'adminadmi2' to a strong, unique credential and restrict network access to the HTTP admin port via firewall rules or network segmentation. Implement rate-limiting and account lockout policies in the authentication handler to prevent brute-force attacks.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
UltravncApplication
Affected:<= 1.8.2.2

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify UltraVNC Repeater installation
    Locate the UltraVNC Repeater executable (repeater.exe or similar) or service on the system. Common paths may include C:\Program Files\UltraVNC\ or C:\Program Files (x86)\UltraVNC\ on Windows systems.
    Affected if UltraVNC Repeater is installed and running on the system
  2. Check installed version
    Right-click the repeater executable, select Properties, and verify the File Version. Compare it against the affected version range: any version up to and including 1.8.2.2 is vulnerable.
    Affected if The installed version is 1.8.2.2 or lower
  3. Verify settings2.txt presence
    Locate the configuration directory for UltraVNC Repeater and check whether the file settings2.txt exists. This file is created after the initial configuration. If absent, the default hardcoded password is active.
    Affected if settings2.txt is missing, meaning the default password 'adminadmi2' is still in use
  4. Confirm HTTP admin server exposure
    Use netstat or a port scanner to verify that TCP port 80 (the HTTP administration interface) is listening and accessible from the network. Check firewall rules to determine if port 80 is exposed externally.
    Affected if The HTTP admin port 80 is open and network-accessible to untrusted parties

The environment is affected if UltraVNC Repeater version 1.8.2.2 or lower is running with settings2.txt absent and its HTTP admin port 80 is network-accessible, as the hardcoded password 'adminadmi2' would be active and exploitable.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 1.8.2.2
Interim mitigation

Immediately change the default admin password from 'adminadmi2' to a strong, unique credential and restrict network access to the HTTP admin port via firewall rules or network segmentation. Implement rate-limiting and account lockout policies in the authentication handler to prevent brute-force attacks.

Fix this in Ultravnc Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA4.0 h
22.0 hours of engineering $3,860
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-7839 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-7839 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data