Simatic Pcs7Application · Siemens

CVE-2014-4684

MEDIUM · 6.0 CVSS v2.0 Published 2014-07-24
Fix available
A fix is available. Upgrade to after 8.0 or later.
See remediation →
66/100
Remediation priority · Elevated
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

The database server component in Siemens SIMATIC WinCC versions before 7.3 contains a privilege escalation vulnerability. An attacker with valid remote authentication credentials can send specially crafted requests to the SQL Server database on TCP port 1433 to gain elevated system privileges beyond what their account should normally have.

MitigationUpgrade Siemens SIMATIC WinCC to version 7.3 or later, which contains the vendor patch. Additionally, restrict network access to port 1433 and follow least-privilege principles for database user accounts.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Simatic Pcs7Application
Affected:<= 8.0= 7.1= 8.0
WinccApplication
Affected:<= 7.2= 5.0= 6.0= 7.0= 7.1

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
M
Authentication
Single
Confidentiality
Partial
Integrity
Partial
Availability
Partial

AV:N/AC:M/Au:S/C:P/I:P/A:P

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify Siemens SIMATIC WinCC or Simatic Pcs7 installation
    Locate the WinCC or Pcs7 installation directory (typically under C:\Program Files\Siemens\WinCC or similar). Check for the presence of WinCC or Pcs7 executables and components.
    Affected if Either Siemens WinCC or Simatic Pcs7 is installed and the version falls within the affected ranges: WinCC <= 7.2, 5.0, 6.0, 7.0, 7.1 or Pcs7 <= 8.0, 7.1, 8.0.
  2. Determine installed WinCC or Pcs7 version
    Check the software version through the Windows Programs and Features list, or locate version information in the WinCC/Pcs7 installation folder (often in a README or version file).
    Affected if The installed version is WinCC 7.2 or earlier, or Pcs7 8.0 or earlier, specifically 5.0, 6.0, 7.0, 7.1 for Wincc and 7.1, 8.0 for Pcs7.
  3. Verify SQL Server is running on port 1433
    Check if Microsoft SQL Server is running and listening on TCP port 1433. Use command 'netstat -an | findstr 1433' or check SQL Server configuration for port 1433.
    Affected if SQL Server is running and accessible on port 1433, which is the database component required for the exploit to be reachable.
  4. Assess network exposure of port 1433
    Determine if port 1433 is exposed to network access beyond the local system or trusted internal networks. Review firewall rules and network segmentation.
    Affected if Port 1433 is accessible from network segments beyond the local localhost, enabling remote attackers to reach the SQL Server.
  5. Review SQL Server authentication configuration
    Check SQL Server authentication mode (Windows or Mixed) and verify which accounts have remote login privileges. Examine SQL Server security logs for authentication attempts.
    Affected if Remote authentication is enabled and valid database credentials exist, providing the attacker with the authentication required to exploit the privilege escalation.

The environment is affected if Siemens WinCC (version 7.2 or earlier) or Simatic Pcs7 (version 8.0 or earlier) is installed with SQL Server running and accessible on port 1433, and remote authentication is enabled.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 8.0
Interim mitigation

Upgrade Siemens SIMATIC WinCC to version 7.3 or later, which contains the vendor patch. Additionally, restrict network access to port 1433 and follow least-privilege principles for database user accounts.

Fix this in Simatic Pcs7 Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA2.0 h
20.0 hours of engineering $3,500
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,600.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2014-4684 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2014-4684 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data