Dp300 FirmwareOperating system · Huawei

CVE-2017-17170

MEDIUM · 6.5 CVSS v3.0 Published 2018-03-09
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
71/100
Remediation priority · Elevated
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
The CIDAM Protocol on some Huawei Products has multiple input validation vulnerabilities due to insufficient validation of specific messages when the protocol is implemented. An authenticated remote attacker could send a malicious message to a target system. Successful exploit could allow the attacker to tamper with business and make the system abnormal. Affected Huawei Products are: DP300 versions V500R002C00, V500R002C00B010, V500R002C00B011, V500R002C00B012, V500R002C00B013, V500R002C00B014, V500R002C00B017, V500R002C00B018, V500R002C00SPC100, V500R002C00SPC200, V500R002C00SPC300, V500R002C00SPC400, V500R002C00SPC500, V500R002C00SPC600, V500R002C00SPC800, V500R002C00SPC900, V500R002C00SPCa00; RP200 versions V500R002C00SPC200, V600R006C00, V600R006C00SPC200, V600R006C00SPC300, V600R006C00SPC400, V600R006C00SPC500; TE30 versions V100R001C10SPC300, V100R001C10SPC500, V100R001C10SPC600, V100R001C10SPC700B010, V500R002C00SPC200, V500R002C00SPC500, V500R002C00SPC600, V500R002C00SPC700, V500R002C00SPC900, V500R002C00SPCb00, V600R006C00, V600R006C00SPC200, V600R006C00SPC300, V600R006C00SPC400, V600R006C00SPC500; TE40 versions V500R002C00SPC600, V500R002C00SPC700, V500R002C00SPC900, V500R002C00SPCb00, V600R006C00, V600R006C00SPC200, V600R006C00SPC300, V600R006C00SPC400, V600R006C00SPC500; TE50 versions V500R002C00SPC600, V500R002C00SPC700, V500R002C00SPCb00, V600R006C00, V600R006C00SPC200, V600R006C00SPC300, V600R006C00SPC400, V600R006C00SPC500; TE60 versions V100R001C10, V100R001C10B001, V100R001C10B002, V100R001C10B010, V100R001C10B011, V100R001C10B012, V100R001C10B013, V100R001C10B014, V100R001C10B016, V100R001C10B017, V100R001C10B018, V100R001C10B019, V100R001C10SPC400, V100R001C10SPC500, V100R001C10SPC600, V100R001C10SPC700, V100R001C10SPC800B011, V100R001C10SPC900, V500R002C00, V500R002C00B010, V500R002C00B011, V500R002C00SPC100, V500R002C00SPC200, V500R002C00SPC300, V500R002C00SPC600, V500R002C00SPC700, V500R002C00SPC800, V500R002C00SPC900, V500R002C00SPCa00, V500R002C00SPCb00, V500R002C00SPCd00, V500R002C00SPCe00, V600R006C00, V600R006C00SPC100, V600R006C00SPC200, V600R006C00SPC300, V600R006C00SPC400, V600R006C00SPC500; eSpace U1981 version V200R003C20SPC900.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

The CIDAM Protocol implementation on affected Huawei products (DP300, RP200, TE30-TE60, eSpace U1981) contains multiple input validation vulnerabilities where specific protocol messages are not properly validated before processing. An authenticated remote attacker can send specially crafted malicious messages to tamper with business operations and cause system abnormal behavior.

MitigationApply vendor-provided patches for affected product versions. As an interim measure, restrict network access to these devices to minimize exposure to authenticated attackers, and monitor for suspicious protocol message patterns.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Dp300 FirmwareOperating system
Affected:= v500r002c00= v500r002c00b010= v500r002c00b011= v500r002c00b012= v500r002c00b013= v500r002c00b014= v500r002c00b017= v500r002c00b018= v500r002c00spc100= v500r002c00spc200= v500r002c00spc300= v500r002c00spc400

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
High
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
High
Availability
High

CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the product model
    Check the device model or product name. For hardware appliances, this is typically displayed in the system information menu or on the device label. For software installations, check the installed product name.
    Affected if The product is Huawei DP300, RP200, TE30, TE60, or eSpace U1981.
  2. Determine the firmware or software version
    Access the device administration interface or system settings to retrieve the current firmware version. Compare the installed version number against the list of affected versions provided for DP300: v500r002c00, v500r002c00b010-b018, v500r002c00spc100-spc400. For RP200, TE30-TE60, and eSpace U1981, obtain the version from the vendor's system information page.
    Affected if The installed version matches any of the affected versions listed in the CVE.
  3. Verify CIDAM Protocol configuration status
    Check the device or software configuration settings for the CIDAM Protocol module. This may be found in the protocol settings, network services, or business communication configuration menus depending on the product interface.
    Affected if The CIDAM Protocol is enabled or configured on the device.
  4. Review protocol message logs for anomalies
    Examine system logs, protocol message logs, or security event logs for unusual or malformed CIDAM protocol messages that may indicate exploitation attempts.
    Affected if Malicious or abnormally formatted CIDAM protocol messages are detected in the logs.

A user is affected if they are running any of the listed product models (DP300, RP200, TE30-TE60, eSpace U1981) with a version matching the affected versions AND the CIDAM Protocol is enabled.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply vendor-provided patches for affected product versions. As an interim measure, restrict network access to these devices to minimize exposure to authenticated attackers, and monitor for suspicious protocol message patterns.

Fix this in Dp300 Firmware Scoped from the published advisory
  • Consultation6.0 h
  • Implementation16.0 h
  • Testing12.0 h
  • Review / QA6.0 h
40.0 hours of engineering $6,960
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $11,136.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2017-17170 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2017-17170 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data