CVE-2017-18833
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedCertain NETGEAR devices are affected by reflected XSS. This affects M4300-28G before 12.0.2.15, M4300-52G before 12.0.2.15, M4300-28G-POE+ before 12.0.2.15, M4300-52G-POE+ before 12.0.2.15, M4300-8X8F before 12.0.2.15, M4300-12X12F before 12.0.2.15, M4300-24X24F before 12.0.2.15, M4300-24X before 12.0.2.15, M4300-48X before 12.0.2.15, and M4200 before 12.0.2.15.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceReflected XSS vulnerability in NETGEAR M4300 series and M4200 switches allows attackers to inject malicious scripts through unsanitized user input that gets reflected back in the web interface response. The vulnerability exists in the HTTP management interface of affected devices.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 12.0.2.15< 12.0.2.15< 12.0.2.15< 12.0.2.15< 12.0.2.15< 12.0.2.15< 12.0.2.15< 12.0.2.15CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- Required
- Scope
- Changed
- Confidentiality
- Low
- Integrity
- Low
- Availability
- None
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device modelAccess the switch CLI or web interface and locate the model name. Affected models are: M4300 28g, M4300 52g, M4300 28g Poe+, M4300 52g Poe+, M4300 8x8f, M4300 12x12f, M4300 24x24f, and M4300 24x.Affected if The device is any of these eight M4300 variants.
-
Verify HTTP management interface is enabledCheck the switch configuration for HTTP or HTTPS management access. This is typically found in the web management UI under Administration > Management Access or via CLI command 'show management'.Affected if The HTTP management interface is enabled and accessible on the network.
-
Check the installed firmware versionIn the web interface, navigate to Maintenance > Firmware Upgrade or Administration > Device View to see the current firmware version. Via CLI, use 'show version' or 'show firmware'.Affected if The firmware version is lower than 12.0.2.15 (for example, 12.0.1.x or earlier).
The device is affected if it is an M4300 series switch with the HTTP management interface enabled and running firmware version lower than 12.0.2.15.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor data12.0.2.15
Upgrade firmware on affected devices to version 12.0.2.15 or later to patch the reflected XSS vulnerability.
- Consultation2.0 h
- Implementation4.0 h
- Testing3.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,088.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2017-18833 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2017-18833 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data