CVE-2018-11462
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). By sending a specially crafted authentication request to the affected systems a remote attacker could escalate his privileges to an elevated user account but not to root. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceAuthentication vulnerability in multiple SINUMERIK CNC systems allows remote attackers to escalate privileges to an elevated user account (non-root) by sending specially crafted authentication requests. The flaw is exploitable over the network with no privileges or user interaction required, potentially compromising system confidentiality, integrity, and availability.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE dataall versionsall versions<= 4.7<= 4.7<= 4.8CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the SINUMERIK CNC modelAccess the CNC HMI and locate the system identification. On Sinumerik 808d, 828d, or 840d sl, the model is typically displayed on the startup screen, under 'System > System Information', or on a system data plate on the control unit.Affected if The model is a Sinumerik 808d, 828d, or 840d sl
-
Determine the firmware versionOn the HMI, navigate to 'System > Version Information' or 'System > Overview' to display the installed firmware version. The version number (such as V4.7, V4.8) is shown in the firmware or software version display.Affected if The firmware version cannot be determined or is not visible
-
Check if version is in affected range for 808dFor Sinumerik 808d, if identified, check whether the firmware version is V4.7 or V4.8 (all versions of these releases are affected per the advisory).Affected if The installed version is Sinumerik 808d with V4.7 or V4.8 firmware
-
Check if version is in affected range for 828dFor Sinumerik 828d, verify if the firmware version is V4.7 or earlier. Versions V4.7 and below are affected; V4.7 SP6 HF1 or later would be patched.Affected if The installed version is Sinumerik 828d with firmware <= V4.7
-
Check if version is in affected range for 840d slFor Sinumerik 840d sl, verify if the firmware is V4.7 (any version <= V4.7) or V4.8 (any version <= V4.8). Versions V4.7 SP6 HF5 or later and V4.8 SP3 or later contain patches.Affected if The installed version is Sinumerik 840d sl with firmware <= V4.7 or <= V4.8
A system is affected if it is a Sinumerik 808d (V4.7 or V4.8), 828d (V4.7 or earlier), or 840d sl (V4.7 or earlier, or V4.8 or earlier) and no vendor patch has been applied.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedApply vendor-supplied patches: update SINUMERIK 828D to V4.7 SP6 HF1 or later, 840D sl V4.7 to V4.7 SP6 HF5 or later, and 840D sl V4.8 to V4.8 SP3 or later. Network segmentation and restricting network access to CNC systems should be implemented as compensating controls until patching is possible.
V4.7 SP6 HF1 or later (828D), V4.7 SP6 HF5 or later (840D sl V4.7), V4.8 SP3 or later (840D sl V4.8), contact vendor for 808D patches
- Contact Siemens through their official support channels (cert-portal.siemens.com or Siemens technical support) to obtain the specific firmware updates
- For Sinumerik 828D V4.7: Upgrade to version V4.7 SP6 HF1 or later
- For Sinumerik 840D sl V4.7: Upgrade to version V4.7 SP6 HF5 or later
- For Sinumerik 840D sl V4.8: Upgrade to version V4.8 SP3 or later
- For Sinumerik 808D V4.7 and V4.8: Contact Siemens for available patches as all versions are affected
- Follow Siemens' official firmware update procedure for your specific Sinumerik model
- Verify the upgrade was successful and the vulnerability is resolved
- Implement network segmentation and access controls to reduce attack surface as a compensating control
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation8.0 h
- Implementation16.0 h
- Testing12.0 h
- Review / QA8.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $12,352.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2018-11462 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2018-11462 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm