Rfid 181 Eip FirmwareOperating system · Siemens

CVE-2018-4833

HIGH · 8.8 CVSS v3.0 Published 2018-06-14
Fix available
A fix is available. Upgrade to 5.2.3 / 5.4.1 or later.
See remediation →
93/100
Remediation priority · Urgent
No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X408 (All versions < V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client's DHCP request.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

The vulnerability allows unprivileged remote attackers on the same local network segment (Layer 2) to achieve remote code execution by sending specially crafted DHCP responses to client DHCP requests. The affected Siemens industrial networking products (RFID readers, RUGGEDCOM Win, SCALANCE switches, and SIMATIC RF182C) lack proper validation of DHCP responses, enabling injection of malicious responses that can trigger code execution.

MitigationIsolate affected devices on dedicated network segments or VLANs to prevent Layer 2 attacks; where possible, implement static IP addressing or DHCP authentication to eliminate the attack surface. Firmware updates should be applied where available (V5.2.3 for X-200, V5.4.1 for X-200IRT, V3.2.6 for X-200RNA, V4.1.3 for X-300/X408).

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Rfid 181 Eip FirmwareOperating system
Affected:all versions
Ruggedcom Wimax FirmwareOperating system
Affected:= 4.4= 4.5
Scalance X200 FirmwareOperating system
Affected:< 5.2.3
Scalance X200irt FirmwareOperating system
Affected:< 5.4.1
Scalance X204rna FirmwareOperating system
Affected:all versions
Scalance X300 FirmwareOperating system
Affected:all versions
Scalance X408 FirmwareOperating system
Affected:all versions
Scalance X414 FirmwareOperating system
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Adjacent
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the device model
    Log into the device or check the physical device label/web interface to determine the exact model (e.g., RFID 181 EIP, RUGGEDCOM Wimax, SCALANCE X200, SCALANCE X200IRT, SCALANCE X204RNA, SCALANCE X300, SCALANCE X408, SCALANCE X414)
    Affected if The device is one of these Siemens industrial networking models: RFID 181 EIP, RUGGEDCOM Wimax, SCALANCE X200, SCALANCE X200IRT, SCALANCE X204RNA, SCALANCE X300, SCALANCE X408, or SCALANCE X414
  2. Determine the firmware version
    Access the device web interface, CLI, or management console and locate the firmware version information. For RUGGEDCOM Wimax, check if version is 4.4 or 4.5. For SCALANCE X200, compare version against 5.2.3. For SCALANCE X200IRT, compare version against 5.4.1. For other models, any version is affected.
    Affected if The device runs: RFID 181 EIP (any version), RUGGEDCOM Wimax (= 4.4 or = 4.5), SCALANCE X200 (< 5.2.3), SCALANCE X200IRT (< 5.4.1), SCALANCE X204RNA (any version), SCALANCE X300 (any version), SCALANCE X408 (any version), or SCALANCE X414 (any version)
  3. Verify DHCP client is enabled
    Check the device network configuration settings to determine if DHCP client mode is active for IP address assignment. Look for DHCP enabled in the network settings, IP configuration, or LAN/DHCP client settings.
    Affected if DHCP client is enabled on the device - the vulnerability is only exploitable when the device requests IP addresses via DHCP from the local network segment

You are affected if you have a listed Siemens industrial networking device with a vulnerable firmware version AND DHCP client is enabled, because the attacker must be on the same Layer 2 network segment to inject malicious DHCP responses.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to 5.2.3 / 5.4.1 or later
Fixed in 5.2.35.4.1
Interim mitigation

Isolate affected devices on dedicated network segments or VLANs to prevent Layer 2 attacks; where possible, implement static IP addressing or DHCP authentication to eliminate the attack surface. Firmware updates should be applied where available (V5.2.3 for X-200, V5.4.1 for X-200IRT, V3.2.6 for X-200RNA, V4.1.3 for X-300/X408).

Fix this in Rfid 181 Eip Firmware Scoped from the published advisory
  • Consultation6.0 h
  • Implementation12.0 h
  • Testing6.0 h
  • Review / QA3.0 h
27.0 hours of engineering $4,800
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,680.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2018-4833 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2018-4833 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data