Io Link Master 4 Eip FirmwareOperating system · Pepperl Fuchs

CVE-2020-12513

HIGH · 8.8 CVSS v3.1 Published 2021-01-22
Fix available
A fix is available. Upgrade to after 1.5.48 or later.
See remediation →
94/100
Remediation priority · Urgent
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to an authenticated blind OS Command Injection.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Pepperl+Fuchs Comtrol IO-Link Master versions 1.5.48 and below contain an authenticated blind OS command injection vulnerability. An attacker with valid credentials can inject malicious OS commands through the affected interface, which are executed without returning output to the attacker (blind injection). This could allow complete compromise of the device.

MitigationUpdate the IO-Link Master firmware to a version newer than 1.5.48. If patching is not immediately feasible, restrict network access to the management interface to trusted IP addresses and enforce strong authentication credentials.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Io Link Master 4 Eip FirmwareOperating system
Affected:<= 1.5.48
Io Link Master 8 Eip FirmwareOperating system
Affected:<= 1.5.48
Io Link Master 8 Eip L FirmwareOperating system
Affected:<= 1.5.48
Io Link Master Dr 8 Eip FirmwareOperating system
Affected:<= 1.5.48
Io Link Master Dr 8 Eip P FirmwareOperating system
Affected:<= 1.5.48
Io Link Master Dr 8 Eip T FirmwareOperating system
Affected:<= 1.5.48
Io Link Master 4 Pnio FirmwareOperating system
Affected:<= 1.5.48
Io Link Master 8 Pnio FirmwareOperating system
Affected:<= 1.5.48

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the IO-Link Master model
    Access the device web interface or administrative console and locate the device information or status page. Confirm the exact product name matches one of the affected variants: IO-Link Master 4 Eip, IO-Link Master 8 Eip, IO-Link Master 8 Eip L, IO-Link Master Dr 8 Eip, IO-Link Master Dr 8 Eip P, IO-Link Master Dr 8 Eip T, IO-Link Master 4 Pnio, or IO-Link Master 8 Pnio.
    Affected if The model matches one of the listed affected products.
  2. Check the installed firmware version
    In the device web interface, navigate to the firmware or software version information section. Record the firmware version number displayed.
    Affected if The firmware version is 1.5.48 or lower.
  3. Verify web management interface accessibility
    Attempt to access the device HTTP/HTTPS management interface from the network. Confirm whether the login page is reachable.
    Affected if The management interface is exposed on the network and accessible without additional network restrictions.
  4. Confirm authentication is configured
    Check if valid user credentials are required to access the management interface. Review the user accounts or authentication settings in the device configuration.
    Affected if The interface uses default or weak credentials, or authentication can be bypassed.

The environment is affected if the device is one of the listed IO-Link Master models with firmware version 1.5.48 or lower and the management interface is network-accessible with valid credentials.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 1.5.48
Interim mitigation

Update the IO-Link Master firmware to a version newer than 1.5.48. If patching is not immediately feasible, restrict network access to the management interface to trusted IP addresses and enforce strong authentication credentials.

Fix this in Io Link Master 4 Eip Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation4.0 h
  • Testing8.0 h
  • Review / QA4.0 h
20.0 hours of engineering $3,440
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,504.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2020-12513 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2020-12513 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data