CVE-2020-14512
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedGateManager versions prior to 9.2c, The affected product uses a weak hash type, which may allow an attacker to view user passwords.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceGateManager versions prior to 9.2c use a weak cryptographic hash function to store user passwords, potentially allowing attackers who obtain the password database to crack the hashes and recover plaintext passwords.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 9.2cCVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- None
- Availability
- None
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify GateManager firmware versionAccess the GateManager web interface or use SSH to connect to the device and retrieve the firmware version information. This is typically visible in the system status or about section of the web UI, or via CLI commands such as 'version' or 'show system info'.Affected if The installed firmware version is prior to 9.2c (for example, 9.2b, 9.2a, or earlier versions).
-
Confirm user authentication is configuredCheck if local user accounts are configured in GateManager. This can be done by reviewing the user management section in the web interface or by checking for the presence of user configuration files in the system.Affected if Local user accounts exist in the GateManager system, as the weak hashing vulnerability only affects stored passwords.
-
Locate password storage databaseIdentify where GateManager stores user password data. This is typically found in configuration directories or database files that contain user authentication information.Affected if The password database or user configuration files are present on the system, as the vulnerability allows cracking of these stored hashes.
The environment is affected if the GateManager 8250 firmware version is below 9.2c and user accounts with stored passwords exist in the system.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor data9.2c
Upgrade to GateManager version 9.2c or later which implements proper password hashing. If immediate upgrade is not possible, implement additional compensating controls such as MFA and network segmentation.
- Consultation4.0 h
- Implementation12.0 h
- Testing6.0 h
- Review / QA3.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,040.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2020-14512 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2020-14512 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data