CVE-2020-15485
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedAn issue was discovered on Nescomed Multipara Monitor M1000 devices. The onboard Flash memory stores data in cleartext, without integrity protection against tampering.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceThe Nescomed Multipara Monitor M1000 stores data in onboard Flash memory in cleartext without any encryption, allowing confidential patient data and device information to be readable. Additionally, the lack of integrity protection means the stored data can be modified or tampered with without detection.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE dataall versionsCVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- None
- Availability
- None
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify device modelLocate the model number on the physical device or check device inventory/system documentation for 'M1000' or 'Multipara Patient Monitor' from Nescomed/NiscomedAffected if Device is confirmed as Nescomed/Niscomed M1000 Multipara Monitor
-
Check if patient data storage is in useReview device configuration or documentation to confirm patient data (vitals, readings, demographics) is being stored on the device's onboard Flash memoryAffected if Patient data is being stored locally on the device Flash memory
-
Verify Flash storage encryption statusExamine device firmware documentation, storage configuration settings, or consult vendor specifications for encryption implementation on the Flash memory storageAffected if Flash memory storage has no encryption enabled or encryption is not documented as implemented
-
Check firmware versionAccess device system information or firmware version display (typically via device menu or service port) to document current firmware versionAffected if Any firmware version is running (affected versions are 'all versions')
If the device is a Nescomed/Niscomed M1000 Multipara Monitor and stores patient data locally in Flash memory without documented encryption, the environment is affected by this vulnerability.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataIsolate affected devices on a restricted network segment to limit exposure; coordinate with Nescomed for a firmware update that implements encryption and integrity verification for Flash memory storage.
- Consultation12.0 h
- Implementation24.0 h
- Testing16.0 h
- Review / QA8.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $16,896.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2020-15485 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2020-15485 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data