Interactive Graphical Scada SystemApplication · Schneider Electric

CVE-2021-22761

HIGH · 7.8 CVSS v3.1 Published 2021-06-11
Fix available
A fix is available. Upgrade to after 15.0.0.21140 or later.
See remediation →
81/100
Remediation priority · High
No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is imported to IGSS Definition.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A buffer overflow vulnerability exists in IGSS Definition (Def.exe) due to missing length validation on user-supplied data when importing CGF files. The lack of bounds checking allows an attacker to overflow a memory buffer during CGF file parsing, potentially enabling information disclosure or remote code execution.

MitigationUpdate IGSS Definition to a patched version beyond V15.0.0.21140. Until a patch is available, avoid importing CGF files from untrusted sources and implement file scanning at the network perimeter.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Interactive Graphical Scada SystemApplication
Affected:<= 15.0.0.21140

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Locate IGSS Definition executable
    Search for Def.exe in the IGSS installation directory, typically under C:\Program Files\Schneider Electric\IGSS\ or C:\Program Files (x86)\Schneider Electric\IGSS\
    Affected if Def.exe exists on the system indicating IGSS is installed
  2. Check IGSS Definition version
    Right-click Def.exe, select Properties, and view the Version tab to obtain the exact product version number
    Affected if The displayed version is 15.0.0.21140 or lower
  3. Verify CGF import functionality
    Open IGSS Definition and navigate to the import or file open dialog to confirm CGF file import capability is present
    Affected if CGF file import feature is accessible and enabled in the application
  4. Confirm IGSS software is in use
    Check running processes for Def.exe or the main IGSS executable (IGSS.exe) indicating the application is actively running or installed
    Affected if IGSS Definition or IGSS SCADA is installed and operational on the system

You are affected if IGSS Definition version is 15.0.0.21140 or lower and CGF file import feature is available on the system.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 15.0.0.21140
Interim mitigation

Update IGSS Definition to a patched version beyond V15.0.0.21140. Until a patch is available, avoid importing CGF files from untrusted sources and implement file scanning at the network perimeter.

Fix this in Interactive Graphical Scada System Scoped from the published advisory
  • Consultation2.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA2.0 h
18.0 hours of engineering $3,100
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,960.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2021-22761 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2021-22761 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data