Sepcos Control And Protection Relay FirmwareOperating system · Secheron

CVE-2022-1666

MEDIUM · 6.5 CVSS v3.1 Published 2022-06-24
Fix available
A fix is available. Upgrade to 1.23.21 / 1.24.8 or later.
See remediation →
71/100
Remediation priority · Elevated
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
The default password for the web application’s root user (the vendor’s private account) was weak and the MD5 hash was used to crack the password using a widely available open-source tool.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

The web application's root account (vendor's private account) used a weak default password that was stored using the insecure MD5 hashing algorithm. Attackers were able to crack this password hash using a publicly available open-source tool, potentially gaining full administrative access.

MitigationReplace the weak default password with a strong, unique password and migrate from MD5 to a modern password hashing algorithm like bcrypt, scrypt, or Argon2.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Sepcos Control And Protection Relay FirmwareOperating system
Affected:>= 1.23.0, < 1.23.21>= 1.24.0, < 1.24.8>= 1.25.0, < 1.25.3

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the firmware version
    Access the Sepcos web interface or management console and navigate to System Information or About section to view the installed firmware version. Alternatively, use the command-line interface or SNMP if available to query the firmware version.
    Affected if The installed version falls within any of these ranges: >= 1.23.0 and < 1.23.21, or >= 1.24.0 and < 1.24.8, or >= 1.25.0 and < 1.25.3
  2. Locate the root account configuration
    In the Sepcos web interface, go to User Management, Administration, or Account Settings section to find the list of user accounts. Identify the root or administrator account.
    Affected if A root or administrator account exists with default credentials still in place (username 'root' or similar default admin account) and has never been changed since deployment.
  3. Inspect password storage mechanism
    If you have administrative access to the device backend or configuration files, examine how passwords are stored. Look for configuration files, database entries, or system files that contain password hashes. Check whether the hash format matches MD5 characteristics (32-character hexadecimal string).
    Affected if Password hashes are stored using MD5 algorithm, which can be identified by the 32-character hexadecimal format and confirmed by attempting to crack with standard MD5 cracking tools.
  4. Verify default password has not been changed
    Compare the current root/administrator password against any documented default passwords provided in Secheron installation manuals. Attempt to log in with known default credentials if you have authorization to do so.
    Affected if The root account password matches the vendor default password or can be easily cracked using publicly available tools within a short timeframe.

Your environment is affected if the firmware version is within the vulnerable ranges AND the root account password remains at its default value stored using MD5 hashing.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 1.23.21 / 1.24.8 / 1.25.3 or later
Fixed in 1.23.211.24.81.25.3
Interim mitigation

Replace the weak default password with a strong, unique password and migrate from MD5 to a modern password hashing algorithm like bcrypt, scrypt, or Argon2.

Recommended fix Moderate confidence

1.23.21, 1.24.8, or 1.25.3 (depending on current branch)

  1. Identify the current firmware version running on the Sepcos Control And Protection Relay device
  2. Determine which version branch you are on (1.23.x, 1.24.x, or 1.25.x)
  3. Obtain the firmware upgrade from the vendor through official channels
  4. Upgrade the firmware to version 1.23.21 or later (if on 1.23.x branch), 1.24.8 or later (if on 1.24.x branch), or 1.25.3 or later (if on 1.25.x branch)
  5. After upgrade, immediately change the default root password to a strong, unique password following vendor password policy
  6. Verify the upgrade was successful and the new password is functioning correctly

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Sepcos Control And Protection Relay Firmware Scoped from the published advisory
  • Consultation2.0 h
  • Implementation4.0 h
  • Testing2.0 h
  • Review / QA1.0 h
9.0 hours of engineering $1,600
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,560.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2022-1666 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2022-1666 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data