CVE-2023-0103
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedIf an attacker were to access memory locations of LS ELECTRIC XBC-DN32U with operating system version 01.80 that are outside of the communication buffer, the device stops operating. This could allow an attacker to cause a denial-of-service condition.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceThis is an out-of-bounds memory access vulnerability in LS ELECTRIC XBC-DN32U PLCs running OS version 01.80. An attacker who accesses memory locations outside the defined communication buffer can trigger a device stop condition, resulting in denial of service.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= 01.80CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- None
- Integrity
- None
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify PLC modelLocate and verify the device model number on the physical PLC hardware or in the device documentation/configuration softwareAffected if Model is LS ELECTRIC XBC-DN32U
-
Check firmware versionAccess the PLC's firmware version information through the vendor's configuration tool, boot menu, or system information interfaceAffected if Firmware version is exactly 01.80
-
Verify communication interface exposureDetermine if the PLC's communication interfaces (Ethernet, serial, or other network protocols) are accessible from network segments beyond the local control networkAffected if Communication interfaces are exposed to untrusted networks or directly accessible without firewall restrictions
-
Confirm PLC is operationalMonitor the PLC runtime status through the vendor's programming software or device diagnosticsAffected if PLC experiences unexpected stop condition or becomes unresponsive during normal communication operations
Your environment is affected if you are running an LS ELECTRIC XBC-DN32U PLC with firmware version 01.80 and the communication interface is network-accessible to potential attackers.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataIf available, apply the vendor firmware update for OS version 01.80. Otherwise, implement network segmentation and restrict access to the PLC's communication interfaces to minimize attack surface.
- Consultation4.0 h
- Implementation8.0 h
- Testing12.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,616.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2023-0103 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2023-0103 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data