Uc 2101 Lx FirmwareOperating system · Moxa

CVE-2023-1257

MEDIUM · 6.8 CVSS v3.1 Published 2023-03-07
Fix available
A fix is available. Upgrade to after 1.5 or later.
See remediation →
73/100
Remediation priority · Elevated
No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
An attacker with physical access to the affected Moxa UC Series devices can initiate a restart of the device and gain access to its BIOS. Command line options can then be altered, allowing the attacker to access the terminal. From the terminal, the attacker can modify the device’s authentication files to create a new user and gain full access to the system.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

An attacker with physical access to Moxa UC Series devices can initiate a device restart, gain BIOS access, modify command line options to access the terminal, and then alter authentication files to create an unauthorized user with full system privileges.

MitigationImplement physical security controls (restricted access to devices), enable BIOS passwords, and disable unauthorized boot options to prevent physical attackers from accessing BIOS and terminal functions.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Uc 2101 Lx FirmwareOperating system
Affected:>= 1.3, <= 1.5
Uc 2102 Lx FirmwareOperating system
Affected:>= 1.3, <= 1.5
Uc 2102 T Lx FirmwareOperating system
Affected:>= 1.3, <= 1.5
Uc 2104 Lx FirmwareOperating system
Affected:>= 1.3, <= 1.5
Uc 2111 Lx FirmwareOperating system
Affected:>= 1.3, <= 1.5
Uc 2112 Lx FirmwareOperating system
Affected:>= 1.3, <= 1.5
Uc 2114 T Lx FirmwareOperating system
Affected:>= 1.3, <= 1.5all versions
Uc 2116 T Lx FirmwareOperating system
Affected:>= 1.3, <= 1.5

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Physical
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify device model
    Check the device label or access the device console and run 'uname -a' or check the web interface to confirm the exact model number (e.g., UC-2101, UC-2102, UC-2104, UC-2111, UC-2112, UC-2114T, UC-2116T)
    Affected if Device is a Moxa UC-2101, UC-2102, UC-2102T, UC-2104, UC-2111, UC-2112, UC-2114T, or UC-2116T series
  2. Check installed firmware version
    Access the device web interface under System > Firmware or run 'cat /etc/moxa-release' or 'moxiadm get system info' from console to obtain the firmware version number
    Affected if Firmware version is >= 1.3 and <= 1.5 (or for UC-2114T, any version)
  3. Verify physical access controls
    Inspect the physical location of the device; verify it is in a locked cabinet, restricted area, or behind controlled access points without public exposure
    Affected if Device is in an accessible public or uncontrolled area where physical attackers could reach it
  4. Confirm BIOS password is set
    Reboot the device and access BIOS setup (typically press Del or F2 during boot); check if a BIOS password is required to enter setup or change boot options
    Affected if BIOS password is not set or BIOS can be accessed without authentication
  5. Check for unauthorized system users
    From console or SSH, run 'cat /etc/passwd' or 'getent passwd' to list all users; check for unknown accounts beyond expected administrator accounts
    Affected if Unexpected users exist in /etc/passwd or authentication files have been modified

The device is affected if it is a Moxa UC-210x or UC-211x series with firmware between 1.3 and 1.5 (or any version for UC-2114T) and lacks physical security, BIOS passwords, or shows unauthorized accounts.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 1.5
Interim mitigation

Implement physical security controls (restricted access to devices), enable BIOS passwords, and disable unauthorized boot options to prevent physical attackers from accessing BIOS and terminal functions.

Fix this in Uc 2101 Lx Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing4.0 h
  • Review / QA2.0 h
18.0 hours of engineering $3,200
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2023-1257 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2023-1257 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data