CVE-2023-34566
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedTenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceStack buffer overflow in Tenda AC10 v4 firmware (US_AC10V4.0si_V16.03.10.13_cn) allows overflow via unsanitized 'time' parameter at /goform/saveParentControlInfo endpoint, enabling remote code execution.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= us_ac10v4.0si_v16.03.10.13_cnCVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device modelAccess the router web interface or check the device label to confirm the model is Tenda AC10Affected if Device is not a Tenda AC10 model
-
Check the firmware versionLog into the router web interface, navigate to System Settings or Firmware Upgrade page, and record the exact firmware version string displayedAffected if Firmware version equals us_ac10v4.0si_v16.03.10.13_cn exactly
-
Verify remote web management is enabledIn the router web interface, check under Advanced Settings or System Settings for 'Remote Web Management' or 'Remote Access' settings. Confirm if it is turned ON allowing access from non-local IP addressesAffected if Remote web management is enabled and the router is directly accessible from the internet
-
Confirm the vulnerable endpoint existsAttempt to access http://[router-ip]/goform/saveParentControlInfo via a browser or curl request. A valid response or authentication prompt indicates the endpoint is presentAffected if The endpoint responds (with or without authentication) indicating Parent Control functionality is loaded
You are affected if your Tenda AC10 runs firmware version us_ac10v4.0si_v16.03.10.13_cn AND the saveParentControlInfo endpoint is accessible (typically via remote web management enabled).
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply vendor firmware update when released; until then, disable remote web management or place device behind firewall to reduce attack surface.
- Consultation2.0 h
- Implementation4.0 h
- Testing3.0 h
- Review / QA1.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,800.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2023-34566 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2023-34566 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm