ViewpowerApplication · Voltronicpower

CVE-2023-51577

HIGH · 7.8 CVSS v3.0 Published 2024-05-03
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
80/100
Remediation priority · High
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Voltronic Power ViewPower setShutdown Exposed Dangerous Method Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Voltronic Power ViewPower. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the setShutdown method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-22023.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Voltronic Power ViewPower contains a vulnerability in the setShutdown method that exposes a dangerous function without proper access controls. An attacker with the ability to execute low-privileged code on the target system can invoke this method to escalate privileges to SYSTEM level and execute arbitrary code. The vulnerability is classified as local privilege escalation (LPE).

MitigationRestrict access to ViewPower installations to trusted users only, ensure the software is patched if vendor updates are available, and consider removing the software if unused. Implement least-privilege principles on systems running ViewPower.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
ViewpowerApplication
Affected:= 1.04.21353

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Locate ViewPower installation
    Search for 'ViewPower' in installed programs (Windows: Control Panel > Programs and Features, or check C:\Program Files or C:\Program Files (x86) for ViewPower folder)
    Affected if ViewPower software is installed on the system
  2. Identify installed version
    Check the version of ViewPower - right-click the executable (typically ViewPower.exe or similar in the installation folder), select Properties, then Details to view File Version
    Affected if The installed version is exactly 1.04.21353
  3. Check service configuration
    Open Services (services.msc), locate the ViewPower service, right-click and select Properties. Check the 'Log on as' field to see if it runs as SYSTEM or another privileged account
    Affected if The ViewPower service runs with elevated privileges (SYSTEM, Local System, or Administrator)
  4. Verify vulnerable component exists
    In the ViewPower installation directory, look for executable files or DLLs that contain the setShutdown method functionality (check for files related to shutdown/scheduled tasks functionality)
    Affected if The vulnerable setShutdown component is present in the installation

A system is affected if ViewPower version 1.04.21353 is installed and the service runs with elevated privileges, allowing a low-privileged user to potentially invoke the vulnerable setShutdown method for privilege escalation.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Restrict access to ViewPower installations to trusted users only, ensure the software is patched if vendor updates are available, and consider removing the software if unused. Implement least-privilege principles on systems running ViewPower.

Fix this in Viewpower Scoped from the published advisory
  • Consultation3.0 h
  • Implementation3.0 h
  • Testing2.0 h
  • Review / QA2.0 h
10.0 hours of engineering $1,800
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,880.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2023-51577 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2023-51577 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data