Tecnomatix Plant SimulationApplication · Siemens

CVE-2024-23796

HIGH · 7.8 CVSS v3.1 Published 2024-02-13
Fix available
A fix is available. Upgrade to 2201.0012 / 2302.0006 or later.
See remediation →
81/100
Remediation priority · High
No privileges Patch available

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis
How this class of weakness works · CWE-122

Data overflows a buffer allocated on the heap, corrupting neighbouring heap structures and allocator metadata that a patient attacker can groom into control of execution. It is subtler than a stack overflow but just as dangerous. The fix is validating lengths before every write and using safe allocators and bounded operations.

General guidance for the heap-based buffer overflow class — the official description and references above are authoritative for this specific CVE. Want a bespoke review and a reviewed fix? Ask our team →

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Tecnomatix Plant SimulationApplication
Affected:< 2201.0012>= 2302.0, < 2302.0006

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 2201.0012 / 2302.0006 or later
Fixed in 2201.00122302.0006
Recommended fix High confidence

V2201.0012 (for V2201 branch) or V2302.0006 (for V2302 branch)

  1. 1. Identify the currently installed Tecnomatix Plant Simulation version by checking 'Help' > 'About' in the application
  2. 2. If running V2201 (any version prior to V2201.0012), plan upgrade to V2201.0012 or later
  3. 3. If running V2302 (any version prior to V2302.0006), plan upgrade to V2302.0006 or later
  4. 4. Obtain the appropriate fixed version installer from Siemens support portal or official distribution channels
  5. 5. Ensure all WRL files are scanned for malware before opening, as the vulnerability is triggered by specially crafted WRL files
  6. 6. Perform the upgrade following standard Siemens installation procedures
  7. 7. After upgrade, verify the application launches correctly and test with legitimate WRL files

Generated from the published advisory — verify against the referenced sources before acting.

We can perform the upgrade in your staging environment and verify nothing breaks — typical engagement from $1,950. Get the upgrade done

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-23796 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-23796 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data