Tecnomatix Plant SimulationApplication · Siemens

CVE-2024-45472

HIGH · 7.8 CVSS v3.1 Published 2024-10-08
Fix available
A fix is available. Upgrade to 2302.0016 / 2404.0005 or later.
See remediation →
81/100
Remediation priority · High
No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. An attacker could leverage this in conjunction with other vulnerabilities to execute code in the context of the current process.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Memory corruption vulnerability in Teamcenter Visualization and Tecnomatix Plant Simulation when parsing specially crafted WRL (VRML) files. An attacker can trigger memory corruption that may allow code execution in the context of the current process by tricking a user into opening a malicious WRL file.

MitigationApply vendor-provided patches: upgrade to Teamcenter Visualization V14.2.0.14+, V14.3.0.12+, V2312.0008+, or Tecnomatix Plant Simulation V2302.0016+, V2404.0005+ to address the memory corruption vulnerability in WRL file parsing.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Tecnomatix Plant SimulationApplication
Affected:< 2302.0016>= 2303.0000, < 2404.0005

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify installed Siemens visualization or simulation product
    Check for installation of Teamcenter Visualization or Tecnomatix Plant Simulation on the system. Look in typical installation directories such as C:\Program Files\Siemens or C:\Program Files (x86)\Siemens, or use system inventory tools to list installed Siemens software.
    Affected if Neither product is installed, then not affected by this specific vulnerability.
  2. Determine installed version of Teamcenter Visualization
    Locate the Teamcenter Visualization installation and check its version. Common locations include the installation directory or check the executable properties (right-click on visualization executable, view Details/Version info). Compare your version against the affected ranges: V14.2.0.0 to V14.2.0.13, V14.3.0.0 to V14.3.0.11, or V2312.0000 to V2312.0007.
    Affected if Installed version falls within the affected ranges and WRL file parsing is accessible.
  3. Determine installed version of Tecnomatix Plant Simulation
    Locate the Tecnomatix Plant Simulation installation and check its version. Access version information through the software's About dialog, installation directory, or Windows Programs and Features. Compare against affected ranges: < 2302.0016 OR >= 2303.0000 and < 2404.0005.
    Affected if Installed version falls within the affected ranges and WRL file parsing is accessible.
  4. Verify WRL file parsing capability is present
    Determine if the WRL (VRML) file parsing component is available in the installed product. This may be confirmed by checking for WRL-related modules, parsers, or file type associations within the software, or by attempting to open a WRL file with the product.
    Affected if WRL parsing capability is present and the version is in the affected range.

User is affected if Teamcenter Visualization or Tecnomatix Plant Simulation is installed with a version matching the affected ranges AND the WRL file parsing feature is available for use.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 2302.0016 / 2404.0005 or later
Fixed in 2302.00162404.0005
Interim mitigation

Apply vendor-provided patches: upgrade to Teamcenter Visualization V14.2.0.14+, V14.3.0.12+, V2312.0008+, or Tecnomatix Plant Simulation V2302.0016+, V2404.0005+ to address the memory corruption vulnerability in WRL file parsing.

Recommended fix High confidence

Tecnomatix Plant Simulation V2302.0016 or later; V2404.0005 or later

  1. 1. Identify the current version of Tecnomatix Plant Simulation installed in your environment
  2. 2. For Tecnomatix Plant Simulation V2302.x: Upgrade to version 2302.0016 or later
  3. 3. For Tecnomatix Plant Simulation V2303.x through V2404.x: Upgrade to version 2404.0005 or later
  4. 4. Alternatively, upgrade to the latest available version of Tecnomatix Plant Simulation for the most complete security coverage
  5. 5. Obtain the update from the official Siemens support portal or through your existing maintenance agreement
  6. 6. Apply the upgrade in a test environment first to validate compatibility with existing simulations and custom scripts
  7. 7. After upgrading, verify that the application launches without errors
  8. 8. Test WRL file import functionality to confirm the vulnerability is remediated
Caveat Review Siemens release notes for your specific version path for any compatibility notes or deprecated features

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Tecnomatix Plant Simulation Scoped from the published advisory
  • Consultation2.0 h
  • Implementation4.0 h
  • Testing6.0 h
  • Review / QA2.0 h
14.0 hours of engineering $2,380
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,808.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-45472 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-45472 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data