NVD · uneditedImproper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in RTI Connext Professional (System Designer) allows OS Command Injection.This issue affects Connext Professional: from 7.0.0 before 7.3.0.2, from 6.1.0 before 6.1.2.19.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceOS Command Injection vulnerability in RTI Connext Professional System Designer allows attackers to execute arbitrary OS commands due to improper neutralization of special elements. This affects versions 7.0.0 through 7.3.0.1 and 6.1.0 through 6.1.2.18, potentially enabling complete system compromise.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data>= 6.1.0, < 6.1.2.19>= 7.0.0, < 7.3.0.2CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify RTI Connext Professional versionCheck the installed version of RTI Connext Professional by examining the product documentation, installation directory, or running the version command if available. Common locations include the installation folder or product metadata files.Affected if The installed version falls within 6.1.0 through 6.1.2.18 OR 7.0.0 through 7.3.0.1 (meaning version is >= 6.1.0 and < 6.1.2.19, or >= 7.0.0 and < 7.3.0.2)
-
Verify System Designer component statusDetermine whether the System Designer component is installed and enabled in the RTI Connext Professional environment. This may be found in the product configuration, modular component list, or feature enablement settings.Affected if System Designer is installed and actively enabled in the environment
-
Assess System Designer network exposureReview network configuration, firewall rules, and access controls to determine if the System Designer service is exposed to the network or accessible remotely.Affected if System Designer is accessible from network locations or has open network listeners
-
Check for unauthorized command executionReview system logs, application logs, and process monitoring for any unexpected or suspicious command executions that may align with the timeframe of the vulnerable version deployment.Affected if Unexpected OS commands or suspicious process activity is found in logs or monitoring tools associated with RTI Connext or System Designer processes
You are affected if RTI Connext Professional version is 6.1.0 through 6.1.2.18 or 7.0.0 through 7.3.0.1 AND the System Designer component is enabled and accessible in your environment.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped6.1.2.197.3.0.2
Upgrade to RTI Connext Professional version 7.3.0.2 or 6.1.2.19 and later. If immediate patching is not feasible, restrict network access to the System Designer component and implement network segmentation to limit exposure.
RTI Connext Professional 7.3.0.2 (or 6.1.2.19 for 6.1.x branch)
- 1. Identify the currently installed RTI Connext Professional version by checking the product documentation or system information
- 2. If running version 6.1.0 through 6.1.2.18, download and install version 6.1.2.19 from the RTI customer portal or official download site
- 3. If running version 7.0.0 through 7.3.0.1, download and install version 7.3.0.2 from the RTI customer portal or official download site
- 4. After installation, verify the new version is correctly installed and the System Designer component is functioning properly
- 5. Test that existing applications and configurations work correctly with the patched version
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation2.0 h
- Implementation4.0 h
- Testing3.0 h
- Review / QA1.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,800.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2024-52058 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2024-52058 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data