Teamcenter VisualizationApplication · Siemens

CVE-2025-23400

HIGH · 7.8 CVSS v3.1 Published 2025-03-11
Fix available
A fix is available. Upgrade to 14.3.0.13 / 2302.0021 or later.
See remediation →
81/100
Remediation priority · High
No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Memory corruption vulnerability in Teamcenter Visualization and Tecnomatix Plant Simulation when parsing specially crafted WRL (VRML) files. The vulnerability allows attackers to achieve code execution in the context of the current process due to insufficient bounds checking during WRL file parsing.

MitigationUpdate affected products to the specified minimum versions: Teamcenter Visualization V14.3.0.13, V2312.0009, V2406.0007, V2412.0002; Tecnomatix Plant Simulation V2302.0021, V2404.0010. Until patches are applied, disable handling of untrusted WRL files and restrict user privileges where possible.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Teamcenter VisualizationApplication
Affected:>= 14.0.0, < 14.3.0.13>= 2312.0, < 2312.0009>= 2406.0, < 2406.0007>= 2412.0, < 2412.0002
Tecnomatix Plant SimulationApplication
Affected:>= 2302.0, < 2302.0021>= 2404.0, < 2404.0010

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm Teamcenter Visualization installation
    Locate the Teamcenter Visualization installation directory (commonly under C:\Program Files\Siemens\TeamcenterVisualization or /usr/siemens/teamcenter_visualization). Look for executable files such as Visualization.exe or related binaries.
    Affected if Teamcenter Visualization is installed and the version falls within any of the affected ranges (>=14.0.0 to <14.3.0.13, >=2312.0 to <2312.0009, >=2406.0 to <2406.0007, or >=2412.0 to <2412.0002)
  2. Confirm Tecnomatix Plant Simulation installation
    Locate the Tecnomatix Plant Simulation installation directory (commonly under C:\Program Files\Siemens\Tecnomatix_Plant_Simulation or similar). Look for the main executable (PlantSimulation.exe or similar).
    Affected if Tecnomatix Plant Simulation is installed and the version falls within any of the affected ranges (>=2302.0 to <2302.0021 or >=2404.0 to <2404.0010)
  3. Determine Teamcenter Visualization version
    Right-click on the main executable (e.g., Visualization.exe), select Properties, and view the Version tab. Alternatively, check the version in the Siemens Licensing Tool or in the product's About dialog accessible from the Help menu.
    Affected if The installed version number is less than the fixed versions: 14.3.0.13, 2312.0009, 2406.0007, or 2412.0002 depending on the release line
  4. Determine Tecnomatix Plant Simulation version
    Open Tecnomatix Plant Simulation, go to Help > About, or right-click the main executable and view the Version tab. The version is typically displayed as a four-digit release (e.g., 2302.0, 2404.0).
    Affected if The installed version number is less than the fixed versions: 2302.0021 or 2404.0010 depending on the release line
  5. Check for WRL file handling capability
    Search the installation directory for WRL-related files, parsers, or converters. Look for file associations or import/export functionality that handles .wrl files. In the product UI, check File > Open or Import for .wrl file type support.
    Affected if The product has the capability to import, open, or parse WRL (VRML) files, which is required for the vulnerability to be exploitable

The environment is affected if either Teamcenter Visualization or Tecnomatix Plant Simulation is installed with a version falling within the affected ranges and WRL file handling functionality is present.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 14.3.0.13 / 2302.0021 / 2312.0009 or later
Fixed in 14.3.0.132302.00212312.0009
Interim mitigation

Update affected products to the specified minimum versions: Teamcenter Visualization V14.3.0.13, V2312.0009, V2406.0007, V2412.0002; Tecnomatix Plant Simulation V2302.0021, V2404.0010. Until patches are applied, disable handling of untrusted WRL files and restrict user privileges where possible.

Recommended fix High confidence

Upgrade to the minimum fixed version for your product line: Teamcenter Visualization V14.3.0.13, V2312.0009, V2406.0007, or V2412.0002; Tecnomatix Plant Simulation V2302.0021 or V2404.0010

  1. 1. Identify the exact version of Teamcenter Visualization or Tecnomatix Plant Simulation currently installed
  2. 2. For Teamcenter Visualization: If running version 14.0.0 to <14.3.0.13, upgrade to V14.3.0.13 or later
  3. 3. For Teamcenter Visualization: If running version 2312.0 to <2312.0009, upgrade to V2312.0009 or later
  4. 4. For Teamcenter Visualization: If running version 2406.0 to <2406.0007, upgrade to V2406.0007 or later
  5. 5. For Teamcenter Visualization: If running version 2412.0 to <2412.0002, upgrade to V2412.0002 or later
  6. 6. For Tecnomatix Plant Simulation: If running version 2302.0 to <2302.0021, upgrade to V2302.0021 or later
  7. 7. For Tecnomatix Plant Simulation: If running version 2404.0 to <2404.0010, upgrade to V2404.0010 or later
  8. 8. Verify the upgrade was successful by checking the application version

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Teamcenter Visualization Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA4.0 h
22.0 hours of engineering $3,860
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-23400 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-23400 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data