Tecnomatix Plant SimulationApplication · Siemens

CVE-2025-25266

MEDIUM · 6.1 CVSS v3.1 Published 2025-03-11
Fix available
A fix is available. Upgrade to 2302.0021 / 2404.0010 or later.
See remediation →
63/100
Remediation priority · Elevated
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application does not properly restrict access to the file deletion functionality. This could allow an unauthorized attacker to delete files even when access to the system should be prohibited, resulting in potential data loss or unauthorized modification of system files.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Tecnomatix Plant Simulation versions V2302 prior to V2302.0021 and V2404 prior to V2404.0010 contain an improper access control vulnerability in the file deletion functionality. An unauthorized attacker could exploit this to delete files on the system, potentially causing data loss or unauthorized modification of system files.

MitigationApply the vendor-supplied patches V2302.0021 or V2404.0010 (or later) to restrict file deletion access to authorized users only.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Tecnomatix Plant SimulationApplication
Affected:>= 2302.0, < 2302.0021>= 2404.0, < 2404.0010

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
High
Availability
Low

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the installed Tecnomatix Plant Simulation version
    Open the application and navigate to Help > About, or check the program files directory for version information
    Affected if The displayed version is any build of V2302 or V2404 prior to the fixed releases
  2. Compare the full version number against the affected ranges
    Locate the complete version string (e.g., 2302.0001 or 2404.0005) and verify it falls within >= 2302.0 but < 2302.0021, or >= 2404.0 but < 2404.0010
    Affected if The version falls within either of the two vulnerable ranges
  3. Confirm the file deletion feature is present
    Check if the application has file manipulation capabilities enabled (this feature is included by default in affected versions)
    Affected if The file deletion functionality exists in the installation (standard in affected versions)

You are affected if your installed version is V2302.x prior to V2302.0021 or V2404.x prior to V2404.0010 and the application file deletion feature is accessible.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 2302.0021 / 2404.0010 or later
Fixed in 2302.00212404.0010
Interim mitigation

Apply the vendor-supplied patches V2302.0021 or V2404.0010 (or later) to restrict file deletion access to authorized users only.

Recommended fix High confidence

V2302.0021 (for 2302 line) or V2404.0010 (for 2404 line)

  1. 1. Identify the current installed version of Tecnomatix Plant Simulation (either V2302.x or V2404.x line)
  2. 2. Navigate to the Siemens official support portal or cert-portal.siemens.com to download the fixed version
  3. 3. For V2302 line users: download version V2302.0021
  4. 4. For V2404 line users: download version V2404.0010
  5. 5. Create a complete backup of all Plant Simulation projects, libraries, and configurations
  6. 6. Install the fixed version following Siemens installation documentation
  7. 7. Verify the installation was successful and confirm the version number
  8. 8. Test that proper file deletion access controls are now enforced

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Tecnomatix Plant Simulation Scoped from the published advisory
  • Consultation3.0 h
  • Implementation2.0 h
  • Testing4.0 h
  • Review / QA2.0 h
11.0 hours of engineering $1,920
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,072.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-25266 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-25266 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data