Intelligent Power ProtectorApplication · Eaton

CVE-2026-22615

HIGH · 7.2 CVSS v3.1 Published 2026-04-16
Fix available
A fix is available. Upgrade to 2.00 or later.
See remediation →
78/100
Remediation priority · High
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Due to improper input validation in one of the Eaton Intelligent Power Protector (IPP) XML, it is possible for an attacker with admin privileges and access to the local system to inject malicious code resulting in arbitrary command execution. This security issue has been fixed in the latest version of Eaton IPP software which is available on the Eaton download centre.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Eaton Intelligent Power Protector contains an improper input validation vulnerability in an XML parameter that allows an authenticated attacker with local system access to inject and execute arbitrary commands. The attack requires both admin privileges and local access to the system, limiting its exploitability but still achieving high impact via command injection.

MitigationUpdate Eaton Intelligent Power Protector to the latest version available from the official Eaton download centre. Ensure admin access controls are reviewed and restrict local system access to trusted personnel only.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Intelligent Power ProtectorApplication
Affected:< 2.00

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
High
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify if Eaton Intelligent Power Protector is installed
    Locate the product in the system via installed programs list, or search for executable files related to Eaton Intelligent Power Protector in common installation directories
    Affected if The product is found installed on the system
  2. Determine the installed version
    Check the version information of the installed Eaton Intelligent Power Protector software (typically via program properties, a version file, or the executable metadata)
    Affected if The installed version is any version prior to 2.00 (for example, 1.x.x or older)
  3. Verify the application is running or configured to run
    Check if the Eaton Intelligent Power Protector service or application is currently active on the system
    Affected if The application is running and exposed for use
  4. Assess local access controls
    Review which user accounts have local system access and admin privileges on the machine where Eaton Intelligent Power Protector is installed
    Affected if Multiple untrusted users have both local login access and admin-level privileges to the system

A user is affected if Eaton Intelligent Power Protector version is installed and is below version 2.00, the application is running, and the system has untrusted users with both local access and admin privileges.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 2.00 or later
Fixed in 2.00
Interim mitigation

Update Eaton Intelligent Power Protector to the latest version available from the official Eaton download centre. Ensure admin access controls are reviewed and restrict local system access to trusted personnel only.

Recommended fix Moderate confidence

Intelligent Power Protector version 2.00 or latest available release

  1. Navigate to the Eaton download centre at www.eaton.com to obtain the latest version of Intelligent Power Protector
  2. Download the most recent Intelligent Power Protector installer
  3. Backup the current configuration and any important data from the existing IPP installation
  4. Stop the Intelligent Power Protector service if it's currently running
  5. Install the new version of Intelligent Power Protector following the vendor's installation instructions
  6. Verify the installation completed successfully
  7. Start the Intelligent Power Protector service
  8. Confirm the application is functioning correctly with the new version
Caveat No specific breaking changes mentioned in the advisory; standard upgrade procedure applies

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Intelligent Power Protector Scoped from the published advisory
  • Consultation4.0 h
  • Implementation4.0 h
  • Testing6.0 h
  • Review / QA3.0 h
17.0 hours of engineering $2,960
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,736.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-22615 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-22615 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data