Intelligent Power ProtectorApplication · Eaton

CVE-2026-22617

HIGH · 7.4 CVSS v3.1 Published 2026-04-16
Fix available
A fix is available. Upgrade to 2.00 or later.
See remediation →
83/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Eaton Intelligent Power Protector (IPP) uses an insecure cookie configuration, which could allow a network‑based attacker to intercept the cookie and exploit it through a man‑in‑the‑middle attack. This security issue has been fixed in the latest version of Eaton IPP software which is available on the Eaton download centre.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Eaton Intelligent Power Protector (IPP) has insecure cookie configuration that fails to set security flags (such as Secure, HttpOnly, or SameSite attributes) on session cookies. This allows a network-based attacker positioned between the client and server to intercept cookies via man-in-the-middle attack and hijack user sessions.

MitigationUpdate Eaton IPP to the latest version available from the Eaton download centre to obtain the vendor patch that fixes the insecure cookie configuration.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Intelligent Power ProtectorApplication
Affected:< 2.00

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
High
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
None

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify if Eaton Intelligent Power Protector is installed
    Check for the installation in common locations: C:\Program Files\Eaton\Intelligent Power Protector, or look for the service named 'IPP' in Windows Services (services.msc), or check for Eaton IPP in Add/Remove Programs
    Affected if The application is present and running on the system
  2. Determine the installed version of Eaton IPP
    Check the version of the installed executable. Common paths: C:\Program Files\Eaton\Intelligent Power Protector\bin\IPP.exe or check the file properties of the main IPP executable. Compare the version number to the affected range (versions before 2.00)
    Affected if The installed version is less than 2.00
  3. Access the IPP web interface to inspect cookies
    Open a web browser and navigate to the Eaton IPP web interface (typically https://localhost or the configured IP address). Open browser Developer Tools (F12), go to the Application tab, and examine cookies under the Application or Storage section
    Affected if The web application is accessible and session cookies are created
  4. Verify cookie security flags
    In browser Developer Tools, examine each cookie set by the IPP application. Check if the 'Secure', 'HttpOnly', and 'SameSite' attributes are present in the Set-Cookie headers or visible in the cookie properties
    Affected if Session cookies are missing one or more of the Secure, HttpOnly, or SameSite attributes, indicating the insecure cookie configuration vulnerability is present

A user is affected if Eaton Intelligent Power Protector version less than 2.00 is installed and running, and session cookies created by the web interface lack Secure, HttpOnly, or SameSite security attributes

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 2.00 or later
Fixed in 2.00
Interim mitigation

Update Eaton IPP to the latest version available from the Eaton download centre to obtain the vendor patch that fixes the insecure cookie configuration.

Recommended fix Moderate confidence

Version 2.00 or later (latest available release from Eaton)

  1. 1. Identify the current version of Eaton Intelligent Power Protector installed in your environment
  2. 2. Back up all IPP configuration data and any critical settings
  3. 3. Navigate to the official Eaton download centre to obtain the latest version of Intelligent Power Protector (version 2.00 or later)
  4. 4. Follow Eaton's documented upgrade procedure to install the new version
  5. 5. After upgrade, verify that cookies are now transmitted with the 'Secure' attribute by inspecting HTTPS responses
  6. 6. Test that all IPP functionality works correctly post-upgrade
Caveat Review Eaton release notes for any configuration changes or migration requirements before upgrading

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Intelligent Power Protector Scoped from the published advisory
  • Consultation2.0 h
  • Implementation2.0 h
  • Testing2.0 h
  • Review / QA1.0 h
7.0 hours of engineering $1,240
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $1,984.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-22617 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-22617 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data