CVE-2026-27767

CRITICAL · 9.8 CVSS v3.1 Published 2026-02-27
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

OCPP WebSocket endpoints lack authentication, allowing unauthenticated attackers to connect using known charging station identifiers and impersonate legitimate chargers. This enables unauthorized command execution and data manipulation within the charging infrastructure.

MitigationImplement strong authentication (e.g., TLS client certificates, token-based auth) for all WebSocket connections to OCPP endpoints and validate station identifiers before accepting connections.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Swtchenergy.comApplication
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify Swtchenergy installation
    Locate any Swtchenergy.com-related services, applications, or web interfaces running in your environment. Check for processes, containers, or services associated with the Swtchenergy platform.
    Affected if Swtchenergy services are found running in the environment
  2. Locate OCPP WebSocket endpoints
    Search for exposed WebSocket endpoints that handle OCPP (Open Charge Point Protocol) communications. These typically accept ws:// or wss:// connections. Review your network configurations, reverse proxies, and application routing to identify OCPP-related WebSocket listeners.
    Affected if OCPP WebSocket endpoints are discovered and accessible on the network
  3. Test endpoint authentication requirements
    Attempt to establish a WebSocket connection to the OCPP endpoints using a known charging station identifier without providing any authentication credentials (tokens, certificates, API keys). Observe whether the connection is accepted or rejected.
    Affected if WebSocket connection succeeds without any authentication credentials
  4. Verify station identifier validation
    Connect to the OCPP WebSocket endpoint using a fabricated or discovered charging station identifier. Check if the system accepts commands from this identifier without performing identity verification or credential validation.
    Affected if The system accepts and processes OCPP commands from unknown or unverified station identifiers

If Swtchenergy is deployed and its OCPP WebSocket endpoints accept connections or commands without requiring authentication or validating station identities, the environment is affected by this vulnerability.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Implement strong authentication (e.g., TLS client certificates, token-based auth) for all WebSocket connections to OCPP endpoints and validate station identifiers before accepting connections.

Fix this in Swtchenergy.com Scoped from the published advisory
  • Consultation8.0 h
  • Implementation16.0 h
  • Testing8.0 h
  • Review / QA4.0 h
36.0 hours of engineering $6,400
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $10,240.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-27767 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-27767 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data