InstrumentstudioApplication · Ni

CVE-2026-48141

HIGH · 7.5 CVSS v3.1 Published 2026-06-19
Fix available
A fix is available. Upgrade to 2.18.0 or later.
See remediation →
84/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
There is a memory leak in NI grpc-device BeginSidebandStream that may result in denial of service due to memory exhaustion.  This affects NI grpc-device 2.17.0 and prior versions.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A memory leak exists in the BeginSidebandStream function of NI grpc-device versions 2.17.0 and prior. When invoked, the function fails to properly deallocate allocated memory resources, causing cumulative memory exhaustion over repeated calls that can lead to denial of service.

MitigationUpgrade NI grpc-device to a version beyond 2.17.0. If upgrade is not immediately feasible, monitor memory usage and consider restarting affected services periodically to prevent memory exhaustion.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
InstrumentstudioApplication
Affected:<= 2025= 2026
Ni Grpc Device ServerApplication
Affected:< 2.18.0

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify installed NI software components
    Check for presence of NI InstrumentStudio or NI Grpc Device Server on the system. Look for installation directories or use system inventory tools to list NI software packages.
    Affected if Either NI InstrumentStudio (any version) or NI Grpc Device Server is installed on the system
  2. Determine NI InstrumentStudio version
    Open NI InstrumentStudio and navigate to Help > About, or check the installed version in the Windows Programs and Features list. Compare the version number to the affected ranges: versions <= 2025 or version 2026.
    Affected if The installed version is 2025 or earlier, or is exactly version 2026
  3. Determine NI Grpc Device Server version
    Check the gRPC Device Server version by running the server executable with a version flag (such as --version or -v), or by inspecting the server binary file properties. Compare against the affected range: versions prior to 2.18.0.
    Affected if The installed NI Grpc Device Server version is less than 2.18.0
  4. Identify BeginSidebandStream usage
    Monitor network traffic or application logs for calls to the BeginSidebandStream function, which is invoked during gRPC communication sessions. Check if the system processes gRPC requests that trigger this function.
    Affected if The system processes gRPC communications that invoke BeginSidebandStream, particularly repeated or bulk requests
  5. Monitor memory consumption
    Use system monitoring tools (such as Task Manager, PerfMon, or similar) to observe the memory footprint of the NI gRPC Device Server process over time. Track memory growth across multiple hours or repeated operations.
    Affected if The NI gRPC Device Server process exhibits continuous memory growth without stabilization, indicating potential memory leak

A system is affected if it runs NI InstrumentStudio versions 2025 or earlier (or version 2026) or NI Grpc Device Server versions prior to 2.18.0, and processes gRPC communications that invoke the BeginSidebandStream function, resulting in observable memory accumulation.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 2.18.0 or later
Fixed in 2.18.0
Interim mitigation

Upgrade NI grpc-device to a version beyond 2.17.0. If upgrade is not immediately feasible, monitor memory usage and consider restarting affected services periodically to prevent memory exhaustion.

Recommended fix High confidence

NI Grpc Device Server 2.18.0

  1. Upgrade NI Grpc Device Server to version 2.18.0 or later to resolve the memory leak in BeginSidebandStream
  2. For Instrumentstudio, verify with NI that your specific version (2025 or 2026) is compatible with grpc-device 2.18.0, or check if NI has released an updated Instrumentstudio version that includes the fixed grpc-device component
  3. After upgrading, monitor memory usage to confirm the memory leak is resolved

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Instrumentstudio Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA4.0 h
22.0 hours of engineering $3,860
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-48141 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-48141 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data