Protect Floodlight FirmwareOperating system · Ui

CVE-2026-55111

HIGH · 7.5 CVSS v3.1 Published 2026-07-02
Fix available
A fix is available. Upgrade to 1.13.6 or later.
See remediation →
84/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A malicious actor with access to the network could exploit a Path Traversal vulnerability found in UniFi Protect Floodlight devices to access files on the UniFi Protect Floodlight.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A path traversal vulnerability exists in UniFi Protect Floodlight devices that allows an unauthenticated attacker with network access to escape the web root directory using traversal sequences (e.g., ../) and read arbitrary files on the underlying filesystem.

MitigationApply the vendor-supplied firmware patch when available; prior to patch deployment, restrict network access to floodlight devices via segmentation and monitor for suspicious path traversal patterns in HTTP requests.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Protect Floodlight FirmwareOperating system
Affected:< 1.13.6

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm device is a UniFi Protect Floodlight
    Access the device web interface or UniFi Protect controller and identify the device model. Look for 'Floodlight' in the device name or model designation.
    Affected if Device model contains 'UniFi Protect Floodlight' or similar designation
  2. Check installed firmware version
    In the UniFi Protect interface, navigate to the device settings or firmware section to view the current firmware version. Compare this version number to 1.13.6.
    Affected if Firmware version is below 1.13.6 (for example, 1.13.5, 1.12.x, or earlier)
  3. Verify network accessibility of floodlight web interface
    From a system on the same network, attempt to reach the floodlight device HTTP interface using its IP address. Confirm the web server is accessible over the network.
    Affected if The floodlight device HTTP port is reachable from untrusted network segments
  4. Inspect HTTP access logs for path traversal patterns
    If accessible, review the device or upstream firewall logs for HTTP requests containing '../' sequences or URL-encoded path traversal attempts targeting the web interface.
    Affected if Logs show requests with '../' or '..%2f' patterns targeting the floodlight device

A user is affected if they have a UniFi Protect Floodlight device running firmware version below 1.13.6 that has its web interface accessible from a network where untrusted parties could send HTTP requests.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 1.13.6 or later
Fixed in 1.13.6
Interim mitigation

Apply the vendor-supplied firmware patch when available; prior to patch deployment, restrict network access to floodlight devices via segmentation and monitor for suspicious path traversal patterns in HTTP requests.

Recommended fix Moderate confidence

Firmware 1.13.6 or later

  1. Access the UniFi Protect controller or UniFi Network application
  2. Navigate to the UniFi Protect devices section
  3. Locate the affected Floodlight device(s)
  4. Check the current firmware version (ensure it is below 1.13.6)
  5. Initiate firmware update through the controller's device management interface
  6. Upgrade to firmware version 1.13.6 or later
  7. Verify the update was successful by checking the firmware version after reboot

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Protect Floodlight Firmware Scoped from the published advisory
  • Consultation2.0 h
  • Implementation2.0 h
  • Testing3.0 h
  • Review / QA1.0 h
8.0 hours of engineering $1,390
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,224.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-55111 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-55111 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data