Powerlogic P7 FirmwareOperating system · Schneider Electric

CVE-2026-9716

HIGH · 7.5 CVSS v3.1 Published 2026-06-25
Fix available
A fix is available. Upgrade to 02.004.001.000 or later.
See remediation →
84/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A NULL pointer dereference vulnerability (CWE-476) in the device's network interface handling allows remote attackers to cause denial of service by sending malformed requests, rendering the HMI and configuration functionality unavailable.

MitigationRestrict network access to exposed interfaces using firewall rules or network segmentation, and apply vendor patches if available.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Powerlogic P7 FirmwareOperating system
Affected:< 02.004.001.000

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Check Powerlogic P7 firmware version
    Access the device HMI or web interface and navigate to System > Information or Device Information to view the firmware version. Alternatively, check via SNMP or console using 'show version' or equivalent command.
    Affected if The firmware version is lower than 02.004.001.000
  2. Verify network interface is enabled
    Navigate to Network Settings or Communications configuration in the device web interface or HMI. Confirm that Ethernet or network interfaces are enabled and configured for communication.
    Affected if Network interface is enabled and the device is reachable over the network
  3. Assess network exposure
    Review firewall rules, VLAN configuration, and network segmentation settings to determine if the device's management interfaces are accessible from untrusted networks.
    Affected if The device's network interface is directly accessible from untrusted or external networks without proper firewall protection

If the Powerlogic P7 firmware version is below 02.004.001.000 and the network interface is enabled and exposed to network requests, the device is vulnerable to CVE-2026-9716.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 02.004.001.000 or later
Fixed in 02.004.001.000
Interim mitigation

Restrict network access to exposed interfaces using firewall rules or network segmentation, and apply vendor patches if available.

Recommended fix High confidence

02.004.001.000 or later

  1. 1. Identify the current firmware version of the Powerlogic P7 device by accessing the device HMI or management interface
  2. 2. Download the updated firmware version 02.004.001.000 or later from the Schneider Electric download portal at download.schneider-electric.com
  3. 3. Review the firmware upgrade instructions in the Schneider Electric product documentation to ensure proper procedures are followed
  4. 4. Create a backup of the current device configuration before proceeding with the firmware update
  5. 5. Apply the firmware update using the manufacturer's recommended method (typically via USB, SD card, or network-based update tool)
  6. 6. After the update completes, verify the device is operational and the HMI and configuration interfaces are accessible
  7. 7. Confirm the firmware version has been updated to 02.004.001.000 or later
Caveat Firmware upgrades may temporarily interrupt device operation; ensure update is performed during a planned maintenance window

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Powerlogic P7 Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing4.0 h
  • Review / QA2.0 h
18.0 hours of engineering $3,200
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-9716 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-9716 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data