Powerlogic P7 FirmwareOperating system · Schneider Electric

CVE-2026-9717

HIGH · 7.2 CVSS v3.1 Published 2026-06-25
Fix available
A fix is available. Upgrade to 02.004.001.000 or later.
See remediation →
78/100
Remediation priority · High
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

OS Command Injection (CWE-78) vulnerability in a network-exposed service allows an authenticated privileged user to execute arbitrary OS commands with elevated privileges, potentially compromising system integrity, confidentiality, and availability.

MitigationImplement strict input validation and sanitize all user-supplied data before using it in OS commands; prefer parameterized APIs or language-specific safe alternatives instead of shell execution functions.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Powerlogic P7 FirmwareOperating system
Affected:< 02.004.001.000

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
High
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the device model
    Access the device web interface, console, or management software and verify the device is a Schneider Electric Powerlogic P7 controller
    Affected if The device is a Powerlogic P7 unit
  2. Check firmware version
    Navigate to the device's system information or firmware version page in the web interface, or use the management CLI command to display the current firmware version (commonly 'show version' or similar)
    Affected if The firmware version is lower than 02.004.001.000 (e.g., 02.003.x.x or earlier)
  3. Verify network-exposed management services
    Review network configuration settings to confirm if web-based management, remote access, or network service interfaces are enabled and accessible from network segments
    Affected if Network management services are enabled and reachable from untrusted networks
  4. Review enabled user accounts
    Check the user account configuration to identify if privileged user accounts with administrative or elevated access rights exist and are active
    Affected if Privileged administrative accounts are configured and enabled on the device

You are affected if the device is a Schneider Electric Powerlogic P7 with firmware version below 02.004.001.000 and has network management interfaces accessible with privileged user accounts enabled.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 02.004.001.000 or later
Fixed in 02.004.001.000
Interim mitigation

Implement strict input validation and sanitize all user-supplied data before using it in OS commands; prefer parameterized APIs or language-specific safe alternatives instead of shell execution functions.

Recommended fix Moderate confidence

Powerlogic P7 Firmware version 02.004.001.000 or later

  1. Obtain the fixed firmware version 02.004.001.000 or later from the official Schneider Electric download portal at download.schneider-electric.com
  2. Review Schneider Electric's official firmware upgrade documentation for Powerlogic P7 devices before proceeding
  3. Backup the current device configuration according to Schneider Electric's backup procedures
  4. Transfer the firmware file to the Powerlogic P7 device using the manufacturer's recommended method (typically via the device's web interface, management port, or dedicated upgrade tool)
  5. Initiate the firmware upgrade process as documented, ensuring stable power supply during the update
  6. After upgrade completes, verify the firmware version has been successfully updated to 02.004.001.000 or later
  7. As a precautionary measure following any command injection incident, change passwords for all privileged accounts that accessed the vulnerable service
  8. Confirm the vulnerability is remediated by verifying the patched firmware is running
Caveat Standard firmware upgrade risks apply - ensure configuration backup before upgrade, and verify compatibility with any integrated systems

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Powerlogic P7 Firmware Scoped from the published advisory
  • Consultation6.0 h
  • Implementation12.0 h
  • Testing8.0 h
  • Review / QA4.0 h
30.0 hours of engineering $5,280
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $8,448.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2026-9717 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2026-9717 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm