Top technology
Linux 13140
Google 12525
Microsoft 12378
Apple 6692
Oracle 6673
Adobe 6383
Ibm 6286
Cisco 5751
Debian 3919
Mozilla 2886
Apache 2864
Redhat 2586
HIGH 8.1
CVE-2022-26393
The Baxter Spectrum WBM is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to ac…
Spectrum Wireless Battery Module Firmware
Mitigation only
CRITICAL 9.8
CVE-2020-12016
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter E…
Em2400 Firmware
Mitigation only
CRITICAL 9.8
CVE-2020-12043
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remain…
Sigma Spectrum Infusion System Firmware
Mitigation only
CRITICAL 9.8
CVE-2020-12045
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a …
Sigma Spectrum Infusion System Firmware
Mitigation only
CRITICAL 9.8
CVE-2020-12047
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wirel…
Sigma Spectrum Infusion System Firmware
Mitigation only
CRITICAL 9.4
CVE-2020-12041
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM th…
Sigma Spectrum Infusion System Firmware
Mitigation only
CRITICAL 9.1
CVE-2020-12032
Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencr…
Em2400 Firmware
Mitigation only
HIGH 7.5
CVE-2020-12048
Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) wh…
Phoenix X36 Firmware
Mitigation only
MEDIUM 6.1
CVE-2020-12012
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter E…
Em2400 Firmware
Mitigation only
MEDIUM 6.1
CVE-2020-12020
Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13 and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 does not restrict non administrative users fro…
Em2400 Firmware
Mitigation only
MEDIUM 6.1
CVE-2020-12024
Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB inte…
Em2400 Firmware
Mitigation only
HIGH 7.5
CVE-2020-12008
Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information w…
Em2400 Firmware
Mitigation only
CRITICAL 9.8
CVE-2014-5432
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/…
Sigma Spectrum Infusion System Firmware
Mitigation only
CRITICAL 9.8
CVE-2014-5433
An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA …
Sigma Spectrum Infusion System Firmware
Mitigation only
MEDIUM 6.8
CVE-2014-5431
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, whi…
Sigma Spectrum Infusion System Firmware
Mitigation only
CRITICAL 9.8
CVE-2014-5434
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-cod…
Sigma Spectrum Infusion System Firmware
Mitigation only