Vulnerability index

Browse CVEs

24 matching
Filters 1 Clear all
Severity

Filters apply as you choose them.

CRITICAL 9.8 CVE-2024-6795 In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gai… Connex Health Portal 2024-08-30+ Fix from $2,3002024-09-09 CRITICAL 9.1 CVE-2024-6796 In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated… Connex Health Portal 2024-08-30+ Fix from $2,3002024-09-09 HIGH 8.1 CVE-2022-26393 The Baxter Spectrum WBM is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to ac… Spectrum Wireless Battery Module Firmware Mitigation only Fix from $1,9502022-09-09 MEDIUM 6.5 CVE-2022-26392 The Baxter Spectrum WBM (v16, v16D38) and Baxter Spectrum WBM (v17, v17D19, v20D29 to v20D32) when in superuser mode is susceptible to format string … Spectrum Wireless Battery Module Firmware after 20d32 Fix from $1,6002022-09-09 MEDIUM 5.4 CVE-2022-26394 The Baxter Spectrum WBM does not perform mutual authentication with the gateway server host. This may allow an attacker to perform a man in the middl… Spectrum Wireless Battery Module Firmware after 20d32 Fix from $1,6002022-09-09 CRITICAL 9.8 CVE-2021-43935 The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the applicatio… Welch Allyn Connex Cardio after 7.0.0 Fix from $2,3002021-12-15 CRITICAL 9.8 CVE-2020-12016 Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter E… Em2400 Firmware Mitigation only Fix from $2,3002020-06-29 CRITICAL 9.8 CVE-2020-12040 Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer … Sigma Spectrum Infusion System Firmware after 6.05 Fix from $2,3002020-06-29 CRITICAL 9.8 CVE-2020-12043 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remain… Sigma Spectrum Infusion System Firmware Mitigation only Fix from $2,3002020-06-29 CRITICAL 9.8 CVE-2020-12045 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a … Sigma Spectrum Infusion System Firmware Mitigation only Fix from $2,3002020-06-29 CRITICAL 9.8 CVE-2020-12047 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wirel… Sigma Spectrum Infusion System Firmware Mitigation only Fix from $2,3002020-06-29 CRITICAL 9.4 CVE-2020-12041 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM th… Sigma Spectrum Infusion System Firmware Mitigation only Fix from $2,3002020-06-29 CRITICAL 9.1 CVE-2020-12032 Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencr… Em2400 Firmware Mitigation only Fix from $2,3002020-06-29 HIGH 7.5 CVE-2020-12036 Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) w… Prismaflex Firmware 3.0+ Fix from $1,9502020-06-29 HIGH 7.5 CVE-2020-12037 Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) w… Prismaflex Firmware 3.0+ Fix from $1,9502020-06-29 HIGH 7.5 CVE-2020-12048 Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) wh… Phoenix X36 Firmware Mitigation only Fix from $1,9502020-06-29 MEDIUM 6.1 CVE-2020-12012 Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter E… Em2400 Firmware Mitigation only Fix from $1,6002020-06-29 MEDIUM 6.1 CVE-2020-12020 Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13 and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 does not restrict non administrative users fro… Em2400 Firmware Mitigation only Fix from $1,6002020-06-29 MEDIUM 6.1 CVE-2020-12024 Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB inte… Em2400 Firmware Mitigation only Fix from $1,6002020-06-29 HIGH 7.5 CVE-2020-12008 Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information w… Em2400 Firmware Mitigation only Fix from $1,9502020-06-29 CRITICAL 9.8 CVE-2014-5432 Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/… Sigma Spectrum Infusion System Firmware Mitigation only Fix from $2,3002019-03-26 CRITICAL 9.8 CVE-2014-5433 An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA … Sigma Spectrum Infusion System Firmware Mitigation only Fix from $2,3002019-03-26 MEDIUM 6.8 CVE-2014-5431 Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, whi… Sigma Spectrum Infusion System Firmware Mitigation only Fix from $1,6002019-03-26 CRITICAL 9.8 CVE-2014-5434 Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-cod… Sigma Spectrum Infusion System Firmware Mitigation only Fix from $2,3002019-03-26