Top technology
Linux 13140
Google 12525
Microsoft 12378
Apple 6692
Oracle 6673
Adobe 6383
Ibm 6286
Cisco 5751
Debian 3919
Mozilla 2886
Apache 2864
Redhat 2586
CRITICAL 9.8
CVE-2021-22801
A CWE-269: Improper Privilege Management vulnerability exists that could cause an arbitrary command execution when the software is configured with sp…
Connexium Network Manager
Mitigation only
CRITICAL 9.8
CVE-2021-22802EPSS 20%
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on …
Interactive Graphical Scada System Data Collector
after 15.0.0.21243
CRITICAL 9.8
CVE-2021-22803
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, w…
Interactive Graphical Scada System Data Collector
after 15.0.0.21243
CRITICAL 9.1
CVE-2021-22805
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user …
Interactive Graphical Scada System Data Collector
after 15.0.0.21243
CRITICAL 9.1
CVE-2021-22823EPSS 21%
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user …
Interactive Graphical Scada System Data Collector
after 15.0.0.21320
HIGH 7.8
CVE-2021-22796
A CWE-287: Improper Authentication vulnerability exists that could allow remote code execution when a malicious file is uploaded. Affected Product: C…
C Gate Server
after 2.11.7
HIGH 7.5
CVE-2021-22787
A CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted …
Modicon M340 Bmxp342020 Firmware
3.40+
HIGH 7.5
CVE-2021-22788
A CWE-787: Out-of-bounds Write vulnerability exists that could cause denial of service when an attacker sends a specially crafted HTTP request to the…
Modicon M340 Bmxp342020 Firmware
3.40+
HIGH 7.5
CVE-2021-22798
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a N…
Conext Combox Firmware
Mitigation only
HIGH 7.5
CVE-2021-22800
A CWE-20: Improper Input Validation vulnerability exists that could cause a Denial of Service when a crafted packet is sent to the controller over ne…
Modicon M218 Firmware
after 5.1.0.6
HIGH 7.5
CVE-2021-22804
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read …
Interactive Graphical Scada System Data Collector
after 15.0.0.21243
HIGH 7.5
CVE-2021-22806
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing…
Spacelynk Firmware
after 2.6.1
HIGH 7.5
CVE-2021-22824EPSS 14%
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on use…
Interactive Graphical Scada System Data Collector
after 15.0.0.21320
HIGH 8.8
CVE-2021-22748
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow a remote code executio…
C Bus Toolkit
after 1.15.9
HIGH 7.5
CVE-2021-22785
A CWE-200: Information Exposure vulnerability exists that could cause sensitive information of files located in the web root directory to leak when a…
Modicon M340 Bmxp342020 Firmware
3.40+
HIGH 7.5
CVE-2022-24318
A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of…
Clearscada
Patch available
HIGH 7.5
CVE-2022-24321
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server …
Clearscada
Patch available
MEDIUM 5.9
CVE-2022-24319
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and…
Clearscada
Patch available
MEDIUM 5.9
CVE-2022-24320
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and…
Clearscada
Patch available
CRITICAL 9.8
CVE-2022-22810
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after …
Spacelynk Firmware
after 2.6.2
CRITICAL 9.8
CVE-2022-22813
A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the…
Easergy P141 Firmware
Mitigation only
CRITICAL 9.8
CVE-2022-24310
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentia…
Interactive Graphical Scada System Data Server
after 15.0.0.22020
CRITICAL 9.8
CVE-2022-24311
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inser…
Interactive Graphical Scada System Data Server
after 15.0.0.22020
CRITICAL 9.8
CVE-2022-24312
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by addin…
Interactive Graphical Scada System Data Server
after 15.0.0.22020
CRITICAL 9.8
CVE-2022-24313EPSS 45%
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remo…
Interactive Graphical Scada System Data Server
after 15.0.0.22020
HIGH 8.8
CVE-2022-22808
A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cro…
Hmibscea53d1edb Firmware
4.0.0.13+
HIGH 8.1
CVE-2022-22811
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could induce users to perform unintended actions, leading to the override of t…
Spacelynk Firmware
after 2.6.2
HIGH 7.5
CVE-2022-24314EPSS 18%
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeated…
Interactive Graphical Scada System Data Server
after 15.0.0.22020
HIGH 7.5
CVE-2022-24315EPSS 19%
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. …
Interactive Graphical Scada System Data Server
after 15.0.0.22020
HIGH 7.5
CVE-2022-24316
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Aff…
Interactive Graphical Scada System Data Server
after 15.0.0.22020