Sunny Boy 3600 FirmwareOperating system · Sma

CVE-2017-9858

HIGH · 7.5 CVSS v3.0 Published 2017-08-05
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
84/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
An issue was discovered in SMA Solar Technology products. By sending crafted packets to an inverter and observing the response, active and inactive user accounts can be determined. This aids in further attacks (such as a brute force attack) as one now knows exactly which users exist and which do not. NOTE: the vendor's position is that this "is not a security gap per se." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

An information disclosure vulnerability in SMA Solar Technology inverters (Sunny Boy TLST-21, TL-21, Sunny Tripower TL-10, TL-30) allows unauthenticated attackers to enumerate valid user accounts by sending crafted packets and analyzing the responses. This user enumeration significantly reduces the effort required for subsequent brute force attacks against the device's authentication mechanism.

MitigationImplement network segmentation to isolate inverters from untrusted networks, deploy firewall rules to restrict access to management interfaces, and monitor for anomalous authentication patterns. If available, apply vendor firmware updates. Consider implementing account lockout policies and rate limiting on authentication endpoints.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Sunny Boy 3600 FirmwareOperating system
Affected:all versions
Sunny Boy 5000 FirmwareOperating system
Affected:all versions
Sunny Tripower Core1 FirmwareOperating system
Affected:all versions
Sunny Tripower 15000tl FirmwareOperating system
Affected:all versions
Sunny Tripower 20000tl FirmwareOperating system
Affected:all versions
Sunny Tripower 25000tl FirmwareOperating system
Affected:all versions
Sunny Tripower 5000tl FirmwareOperating system
Affected:all versions
Sunny Tripower 12000tl FirmwareOperating system
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the inverter model and firmware version
    Access the device web interface or check the device labeling/documentation. Look for the model number (e.g., Sunny Boy 3600, Sunny Tripower 15000tl) and note that all firmware versions are affected.
    Affected if The device is one of: Sunny Boy 3600, Sunny Boy 5000, Sunny Tripower Core1, Sunny Tripower 15000tl, Sunny Tripower 20000tl, Sunny Tripower 25000tl, Sunny Tripower 5000tl, or Sunny Tripower 12000tl.
  2. Confirm network accessibility of the management interface
    Attempt to access the device web interface on typical ports (80, 443, 8080) from a remote location or verify the device IP is routable from untrusted networks.
    Affected if The web-based management interface is accessible from networks outside the trusted internal network.
  3. Test for user enumeration vulnerability
    Send multiple authentication requests with different usernames to the login endpoint and observe the responses. Look for differences in response time, error messages, or HTTP status codes that reveal which usernames are valid.
    Affected if The device returns distinct responses that differentiate between valid and invalid usernames, allowing an attacker to enumerate existing accounts.
  4. Review authentication logs for enumeration patterns
    If accessible, examine the device logs or syslog exports for repeated authentication attempts with varying usernames, especially from single source IPs.
    Affected if Logs show patterns of failed login attempts with many different usernames, indicating enumeration activity.

A user is affected if they operate any of the listed SMA inverter models with the management interface exposed to accessible networks, as the vulnerability enables unauthenticated user account enumeration.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Implement network segmentation to isolate inverters from untrusted networks, deploy firewall rules to restrict access to management interfaces, and monitor for anomalous authentication patterns. If available, apply vendor firmware updates. Consider implementing account lockout policies and rate limiting on authentication endpoints.

Fix this in Sunny Boy 3600 Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation6.0 h
  • Testing3.0 h
  • Review / QA2.0 h
15.0 hours of engineering $2,690
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,304.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2017-9858 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2017-9858 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data