Mycarelink 24952 Patient Monitor FirmwareOperating system · Medtronic

CVE-2018-10622

MEDIUM · 5.2 CVSS v3.1 Published 2018-08-10
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
57/100
Remediation priority · Elevated
No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

The Medtronic MyCareLink Patient Monitor stores per-product authentication credentials in a recoverable format rather than using proper cryptographic protection. An attacker who can extract these credentials from the device can leverage them for network authentication to access the device or associated systems.

MitigationNetwork segmentation should isolate medical devices from untrusted networks; monitor for unauthorized authentication attempts using the compromised credential format. The definitive fix requires Medtronic to release a firmware update implementing proper credential protection.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Mycarelink 24952 Patient Monitor FirmwareOperating system
Affected:all versions
Mycarelink 24950 Patient Monitor FirmwareOperating system
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Physical
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
High
Availability
None

CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the device model
    Locate the model number printed on the physical device or check the device inventory/system documentation to confirm the exact model designation (24952 or 24950)
    Affected if The device model is MyCareLink 24952 or MyCareLink 24950 Patient Monitor
  2. Check the installed firmware version
    Access the device settings or administrative interface to retrieve the firmware version information, or consult the device management console if centrally managed
    Affected if Any firmware version is installed on the affected models (all versions are vulnerable)
  3. Inspect credential storage configuration
    Examine the device configuration files or credential storage mechanism through the device administrative interface or by reviewing exported device configurations for authentication credential storage
    Affected if Credentials are stored in a recoverable or non-cryptographically protected format

You are affected if your environment contains a MyCareLink 24952 or 24950 Patient Monitor, as all firmware versions store credentials in a recoverable format rather than using proper cryptographic protection.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Network segmentation should isolate medical devices from untrusted networks; monitor for unauthorized authentication attempts using the compromised credential format. The definitive fix requires Medtronic to release a firmware update implementing proper credential protection.

Fix this in Mycarelink 24952 Patient Monitor Firmware Scoped from the published advisory
  • Consultation8.0 h
  • Implementation16.0 h
  • Testing8.0 h
  • Review / QA4.0 h
36.0 hours of engineering $6,400
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $10,240.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2018-10622 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2018-10622 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data