Nx OsOperating system · Cisco

CVE-2019-1608

MEDIUM · 6.7 CVSS v3.1 Published 2019-03-08
Fix available
A fix is available. Upgrade to 6.2 / 7.3 or later.
See remediation →
69/100
Remediation priority · Elevated
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(27), 8.1(1b), and 8.3(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3).

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

This is a command injection vulnerability in the Cisco NX-OS CLI where insufficient validation of arguments passed to certain CLI commands allows an authenticated local attacker with administrator credentials to execute arbitrary commands on the underlying operating system with elevated privileges. The attacker exploits this by including malicious input as arguments to affected commands.

MitigationUpgrade Cisco NX-OS software to version 6.2(27) or later for MDS 9000 Series, or 6.2(22)/7.3(3)D1(1)/8.2(3) or later for Nexus 7000/7700 Series. Restrict administrator access to trusted personnel only.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Nx OsOperating system
Affected:>= 8.2, < 8.3\(1\)>= 7.3, < 8.1\(1b\)>= 5.2, < 6.2\(27\)> 8.0, < 8.2\(3\)> 7.2, < 7.3\(3\)d1\(1\)< 6.2\(22\)

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
High
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Determine Cisco NX-OS version
    Log into the device CLI and run 'show version' command. Look for the software version number in the output.
    Affected if The displayed version falls within any of these ranges: >= 8.2 but < 8.3(1); >= 7.3 but < 8.1(1b); >= 5.2 but < 6.2(27); > 8.0 but < 8.2(3); > 7.2 but < 7.3(3)D1(1); or < 6.2(22)
  2. Confirm the device is a Nexus or MDS series
    The 'show version' output also displays the hardware platform. Verify if it is a Cisco Nexus 7000/7700 Series switch or MDS 9000 Series switch.
    Affected if The device is a Nexus 7000/7700 or MDS 9000 Series running an affected NX-OS version from step 1
  3. Verify local administrator access exists
    This vulnerability requires an authenticated local attacker with administrator credentials. Determine if local user accounts with administrator privileges exist on the system using 'show user account' or by reviewing AAA configuration.
    Affected if Local authentication with administrator-level privileges is configured or possible on the device

You are affected if your Cisco Nexus or MDS device runs an NX-OS version in the affected ranges AND allows local authentication with administrator credentials, since the attacker needs both conditions to exploit this command injection flaw.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to 6.2 / 7.3 / 8.1 or later
Fixed in 6.27.38.1
Interim mitigation

Upgrade Cisco NX-OS software to version 6.2(27) or later for MDS 9000 Series, or 6.2(22)/7.3(3)D1(1)/8.2(3) or later for Nexus 7000/7700 Series. Restrict administrator access to trusted personnel only.

Fix this in Nx Os Scoped from the published advisory
  • Consultation4.0 h
  • Implementation4.0 h
  • Testing2.0 h
  • Review / QA2.0 h
12.0 hours of engineering $2,180
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,488.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2019-1608 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2019-1608 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data