Factorytalk DiagnosticsApplication · Rockwellautomation

CVE-2020-5807

HIGH · 7.5 CVSS v3.1 Published 2020-12-29
Fix available
A fix is available. Upgrade to after 6.11 or later.
See remediation →
84/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

An unauthenticated remote attacker can send specially crafted data to RsvcHost.exe listening on TCP port 5241 to inject entries with excessively long fields into the FactoryTalk Diagnostics event log. When a legitimate local user subsequently opens FTDiagViewer.exe to view these log entries, the overly long field values trigger an unhandled exception in the wcscpy_s() function, causing the viewer to crash.

MitigationRestrict network access to TCP port 5241 (e.g., firewall rules, network segmentation) to prevent unauthenticated attackers from injecting malicious log entries, and limit local user access to FactoryTalk Diagnostics Viewer until an official vendor patch is released.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Factorytalk DiagnosticsApplication
Affected:<= 6.11

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Verify FactoryTalk Diagnostics is installed
    Check installed programs or product registry for FactoryTalk Diagnostics component
    Affected if The product is present on the system
  2. Check installed version against affected range
    Locate and read the FactoryTalk Diagnostics version information, then compare to 6.11
    Affected if Version is 6.11 or lower
  3. Verify RsvcHost.exe is listening on TCP port 5241
    Run netstat -an | findstr 5241 or use PortQry to check if port 5241 is in listening state
    Affected if Port 5241 is open and accepting connections (RsvcHost.exe service running)
  4. Inspect FactoryTalk Diagnostics log for unusually long field entries
    Open the diagnostic log storage location and search for entries with abnormally long string fields, or use FTDiagViewer.exe to browse recent entries
    Affected if Log contains entries with excessively long field values that exceed normal length

A user is affected if FactoryTalk Diagnostics version 6.11 or lower is installed AND port 5241 is accessible, allowing potential injection of malicious log entries with oversized fields.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 6.11
Interim mitigation

Restrict network access to TCP port 5241 (e.g., firewall rules, network segmentation) to prevent unauthenticated attackers from injecting malicious log entries, and limit local user access to FactoryTalk Diagnostics Viewer until an official vendor patch is released.

Fix this in Factorytalk Diagnostics Scoped from the published advisory
  • Consultation2.0 h
  • Implementation4.0 h
  • Testing3.0 h
  • Review / QA1.0 h
10.0 hours of engineering $1,750
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,800.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2020-5807 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2020-5807 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data