Halo\+ Camera FirmwareOperating system · Binatoneglobal

CVE-2021-3793

MEDIUM · 5.3 CVSS v3.1 Published 2021-11-12
Fix available
A fix is available. Upgrade to 03.40.00 / 03.40.02 or later.
See remediation →
62/100
Remediation priority · Elevated
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
An improper access control vulnerability was reported in some Motorola-branded Binatone Hubble Cameras which could allow an unauthenticated attacker on the same network as the device to access administrative pages that could result in information disclosure or device firmware update with verified firmware.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

This is an improper access control vulnerability in Motorola-branded Binatone Hubble Cameras where administrative web interfaces lack proper authentication, allowing any unauthenticated attacker on the same local network to access sensitive admin pages. This can lead to information disclosure (configuration, credentials, video feeds) and firmware updates using seemingly verified firmware images.

MitigationIsolate affected camera devices on a dedicated VLAN or network segment to limit attack surface, implement network access controls restricting administrative interface access to authorized management stations only, and check manufacturer for firmware updates.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Halo\+ Camera FirmwareOperating system
Affected:< 03.50.14
Comfort 85 Connect FirmwareOperating system
Affected:< 03.40.02
Mbp3855 FirmwareOperating system
Affected:< 03.40.00
Focus 68 FirmwareOperating system
Affected:all versions
Focus 72r FirmwareOperating system
Affected:< 03.40.00
Cn28 FirmwareOperating system
Affected:all versions
Cn50 FirmwareOperating system
Affected:all versions
Comfort 40 FirmwareOperating system
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the camera model
    Locate the model number on the camera device label or check the Hubble app/device documentation to determine if it is one of: Halo+ Camera, Comfort 85 Connect, Mbp3855, Focus 68, Focus 72r, Cn28, Cn50, or Comfort 40
    Affected if The device is any of these Binatoneglobal camera models
  2. Check the installed firmware version
    Access the camera's web interface (typically at the camera's IP address on the local network) and navigate to Settings > Device Info > Firmware Version, or check via the Hubble mobile app under device settings
    Affected if The firmware version is below 03.50.14 for Halo+, below 03.40.02 for Comfort 85 Connect, below 03.40.00 for Mbp3855 or Focus 72r, or any version for Focus 68, Cn28, Cn50, or Comfort 40
  3. Verify the admin web interface is network-accessible
    Confirm the camera is connected to the local network and accessible via HTTP/HTTPS on its IP address (common ports 80, 443, or 8080)
    Affected if The admin web interface responds to HTTP requests from other devices on the local network
  4. Test for unauthenticated admin access
    Attempt to access common admin paths such as /admin, /settings, /config, or /device.html without providing any login credentials
    Affected if The admin pages load and display sensitive information (configuration, credentials, firmware update options) or allow firmware upload without requiring any authentication

The device is affected if it is a Binatoneglobal Halo+, Comfort 85 Connect, Mbp3855, Focus 68, Focus 72r, Cn28, Cn50, or Comfort 40 camera with a firmware version in the affected range AND the admin web interface is accessible without authentication on the local network

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 03.40.00 / 03.40.02 / 03.50.14 or later
Fixed in 03.40.0003.40.0203.50.14
Interim mitigation

Isolate affected camera devices on a dedicated VLAN or network segment to limit attack surface, implement network access controls restricting administrative interface access to authorized management stations only, and check manufacturer for firmware updates.

Recommended fix Moderate confidence

Upgrade to specific fixed firmware versions: Halo+ to 03.50.14, Comfort 85 Connect to 03.40.02, Mbp3855 to 03.40.00, Focus 72r to 03.40.00

  1. 1. Identify the exact model of your Motorola/Binatone Hubble camera from the affected product list
  2. 2. For Halo+ Camera: upgrade firmware to version 03.50.14 or later
  3. 3. For Comfort 85 Connect: upgrade firmware to version 03.40.02 or later
  4. 4. For Mbp3855: upgrade firmware to version 03.40.00 or later
  5. 5. For Focus 72r: upgrade firmware to version 03.40.00 or later
  6. 6. For Focus 68, Cn28, Cn50, and Comfort 40: no fixed firmware version is available; apply network segmentation to isolate these devices
  7. 7. Implement network segmentation (VLAN) to isolate camera devices from untrusted networks
  8. 8. Place affected devices behind a firewall and restrict access to trusted IP addresses only
Caveat Firmware updates may reset device configuration; backup settings before upgrading if possible

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Halo\+ Camera Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing4.0 h
  • Review / QA2.0 h
18.0 hours of engineering $3,200
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2021-3793 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2021-3793 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data