Factorytalk ViewApplication · Rockwellautomation

CVE-2024-4609

CRITICAL · 9.8 CVSS v3.1 Published 2024-05-16
Fix available
A fix is available. Upgrade to 11.0 or later.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability exists in the Rockwell Automation FactoryTalk® View SE Datalog function that could allow a threat actor to inject a malicious SQL statement if the SQL database has no authentication in place or if legitimate credentials were stolen. If exploited, the attack could result in information exposure, revealing sensitive information. Additionally, a threat actor could potentially modify and delete the data in a remote database. An attack would only affect the HMI design time, not runtime.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

FactoryTalk View SE Datalog function contains a SQL injection vulnerability exploitable when the SQL database lacks authentication or if attacker obtains legitimate credentials, allowing exposure of sensitive data or modification/deletion of database records. The attack surface is limited to HMI design-time environments, not runtime operations.

MitigationImplement database authentication and enforce proper credential management to prevent unauthorized SQL injection through the Datalog function.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Factorytalk ViewApplication
Affected:< 11.0

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify installed FactoryTalk View SE version
    Open Windows Control Panel > Programs and Features, or launch FactoryTalk View SE and check Help > About. Locate the version number.
    Affected if Version is below 11.0 (for example, 10.0 or earlier)
  2. Confirm Datalog function is configured
    Open FactoryTalk View SE application, navigate to the Datalog configuration area (typically under Application Setup or Runtime Setup menus), and verify if any Datalog database connection is defined.
    Affected if A Datalog database connection exists and is enabled in the HMI project
  3. Verify SQL database authentication status
    Inspect the Datalog database connection settings within FactoryTalk View SE. Check whether the SQL database connection string includes login credentials or is configured to connect without authentication (blank username/password).
    Affected if The database connection uses no authentication (empty username and password fields) OR uses default/weak credentials
  4. Assess design-time environment exposure
    Confirm the system is used for HMI development/design (not just runtime operations). Check if FactoryTalk View Studio or the SE development environment is installed and accessible.
    Affected if The vulnerable software is installed as a design-time development environment

You are affected if FactoryTalk View SE version is below 11.0, the Datalog function is configured with a SQL database that lacks proper authentication, and the system is used as a design-time HMI environment.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 11.0 or later
Fixed in 11.0
Interim mitigation

Implement database authentication and enforce proper credential management to prevent unauthorized SQL injection through the Datalog function.

Recommended fix High confidence

FactoryTalk View SE version 11.0 or later

  1. 1. Identify current FactoryTalk View SE version installed in the environment
  2. 2. Create a full backup of the FactoryTalk View project files, HMI applications, and database configurations
  3. 3. Download FactoryTalk View SE version 11.0 or later from the official Rockwell Automation website or their download portal
  4. 4. Review Rockwell Automation installation documentation and release notes for version 11.0
  5. 5. Install FactoryTalk View SE version 11.0 on the design-time workstation
  6. 6. After upgrade, ensure the SQL database has proper authentication enabled (this was a prerequisite condition for exploitation)
  7. 7. Verify the Datalog function operates correctly in the upgraded version
  8. 8. Test that the HMI design-time components function as expected
Caveat Review release notes for version 11.0; major version upgrades may introduce interface changes or require revalidation of HMI projects

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Factorytalk View Scoped from the published advisory
  • Consultation6.0 h
  • Implementation12.0 h
  • Testing6.0 h
  • Review / QA4.0 h
28.0 hours of engineering $4,980
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,968.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-4609 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-4609 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data